manufacturers for the latest specifications and the cost of mobile home chimney system parts or a
mobile home chimney kit.
TABLE 4: MOBILE HOME (minimum) VENT SYSTEM REQUIRED PARTS
PART NUMBER
DESCRIPTION
QTY
4PRC
VERTICAL CHIMNEY CAP 4” OVER TEN FEET
1
4PF
STANDARD ROOF FLASHING
1
4P36
THREE FOOT VENT PIPE, 4”
1
4PRS ROOF
SUPPORT
1
4P60
FIVE FOOT VENT PIPE, 4”
1
4PT3
3” TO 4” CLEAN OUT “T”
1
CERAFORM 126
WALL PROTECTION ( IF REQUIRED)
1
3PSAU
UNVERSAL STOVE ADPATER
1
4PSC STORM
COLLAR
1
NOTE: The information provided in TABLE 4 and detailed in FIGURE 18 are for EXAMPLE only.
Vent systems are affected by local site conditions and local codes. Consult a certified professional and
insure that any mobile home Harvester vent system installation meets all federal, state, and local building
codes. Failure to follow the chimney manufacturer’s installation instructions will void Country Flame’s
product warranty. Failure to utilize a certified installation will void the warrant and may have an adverse
impact on the homeowner’s insurance policy. One of the major causes of mobile home fires is
improperly installed and operated heating systems. Contact Country Flame or one of its local authorized
dealers to resolve any questions about installation or parts usage.