All directions in the room must be swept. A few minutes should be enough to disinfect
a standard-sized room.
After the disinfection process, the disinfected surfaces will be "slightly moist".
If the moistening is too intense then carefully adjust (closing) the liquid supply
regulating valve (16).
9.
END OF OPERATION
Disinfection can be paused just closing the Liquid Supply Regulating Valve (
Close 16
)
and the Air Line Valve (
Close 17
).
The COUNTERFOG® SDR-F05A+ can be then unplugged, moved to another room and
plugged again. The tank will remain pressurized.
To end the operation, unplug the COUNTERFOG® SDR-F05A+ equipment, move it to a
safe place and proceed to depressurization:
Close the Liquid Supply Regulating Valve (
Close 16
), the Air Line Valve (
Close
17
) and the Liquid supply valve (
Close 10
).
Press the OFF button
of the KAESER icomp3 compressor (12) (
RED
).
Carefully release and open the interlocking vent valve (
Open 6
). Wait until
pressure in the tank becomes that of atmosphere (no air flows out at that
time).
Unplug the equipment
from the 230 V supply line.
Connect the Filling hose (2) to the Inlet quick connection (3)
. Open the filling
valve (
Open 4
) and
check that Liquid supply valve (10) remain closed
. Keep
the filling hose (2) lower than the filling valve (4) and poor the remaining liquid
into a container using the filling hose. Dispose any liquid according to the
recommendations of the liquid manufacturer.
Summary of Contents for SDR-F05A+
Page 1: ...COUNTERFOG SDR F05A USER MANUAL September 2020...
Page 9: ...COUNTERFOG SDR F05A User Manual COUNTERFOG EBT de la UAH S L 9 3 2 COMPONENTS...
Page 11: ...COUNTERFOG SDR F05A User Manual COUNTERFOG EBT de la UAH S L 11...
Page 12: ...COUNTERFOG SDR F05A User Manual COUNTERFOG EBT de la UAH S L 12...
Page 13: ...COUNTERFOG SDR F05A User Manual COUNTERFOG EBT de la UAH S L 13...