Counterfog® PILAR can be then unplugged, moved to another room and plugged
again. The tank will remain pressurized.
o
Unplug the equipment
from the 120 V/60 Hz supply line.
To end the operation, unplug the Counterfog® PILAR device, move it to a safe place
and proceed to depressurization:
o
Double check
all valves (3 “FILL”, 4 “EMPTY”, 6 “LIQUID”, 7 “AIR” and
11 “VENT”) are closed
.
o
Carefully release and open the vent valve (
Open 11 “VENT”
). Wait until
pressure in the tank becomes the atmospheric (no air flows out at that
time).
o
To evacuate the remaining liquid from Counterfog® PILAR, place a
suitable container (compatible with the disinfectant) under the device
since the residual disinfectant will come out through the Teflon hose
indicated in the following image.
o
Open valve 4 (
open 4 “EMPTY”
) and the liquid is evacuated.
Always wear gloves and safety glasses when evacuating the residual liquid from the
device!