35
6.
RS-232 Command
6-1-3. Command for accessing Setup Menus and adjusting values
<Function Code>
Setting Menu
<Function Code>
Setting Menu
FUNC0
OVP Setting
FUNC10
Shut-down retry
FUNC1
OVP Recovery
FUNC11
Saving Level
FUNC2
UVP Setting
FUNC12
Saving Interval
FUNC3
UVP Recovery
FUNC13
Bypass Relay
FUNC4
UV Alarm
FUNC14
LCD Contrast
FUNC5
O/P Voltage
FUNC15
LCD Auto-off
FUNC6
RS-232 Baud rate
FUNC16
Buzzer Setting
FUNC7
O/P Frequency
FUNC17
Alert Setting
FUNC8
Sync Frequency
FUNC18
Language
FUNC9
Overload Alarm
Table 28. Command for accessing setup menus and adjusting values
1. Select the Setup Menus with the help of Function Codes
Format FUNC <Function Code>
After “Enter”, the Setup Menu for the Function Code will be called.
The <Function Code>= 0~18
2. Command to query the Functions No
Format FUNC?
After “Enter”, the unit’s “Function Code” appears on the PC screen.
3. Command to query the set value of the Function
Format SETT?
After “Enter”, the existing set value of the function appears on the PC
screen.
4. Command to set or adjust the value of the Function
Format SETT <value>
After “Enter”, the new value of the Function is set Choose the <value> of the
function.
6-1-4. Setting interface
1. OVP Setting
<FUNC0>
Set the Over Voltage Protection (OVP) and
shutdown.
Default = 16 VDC @ 12V Model, 32 VDC @ 24V Model, 64 VDC @ 48V
Model
Model
Setting value range
12 V
15 VDC ~ 16 VDC
24 V
30 VDC ~ 32 VDC
48 V
60 VDC ~ 64 VDC
Table 29. OVP Setting <FUNC0>