![Cotek S600 Series User Manual Download Page 6](http://html.mh-extra.com/html/cotek/s600-series/s600-series_user-manual_2672727006.webp)
2-2. Electrical Performance
3
Specification
Model No.
Item
S600-112 S600-124 S600-148 S600-212 S600-224 S600-248
AC Voltage
Rated Power
100 / 110 / 120 VAC ± 5%
600W
Surge Power
800W
Max. Output Power
(3Min.)
680W
Waveform
Pure Sine Wave (THD < 3%)
Frequency
(Switch Selections)
50 / 60Hz ± 0.5%
Standard Receptacles
Output Voltage Regulation
No Load Current Draw
0.87A
0.43A
0.43A
Red / Orange / Green LED
0.23A
0.22A
0.83A
DC Voltage
12V
Efficiency (Typ.)
87%
Protection
Input Level Indicator
Load Level Indicator
-30 ~ 70
o
C, 10~95% RH
Storage Temp. & Humidity
0 ~ 40
o
C
Working Temperature
Red LED
Failure Indicator
I/P – O/P: 100M Ohms / 500VDC
Isolation Resistance
Loading controlled cooling fan
Cooling
179x72x273 mm / 7.05x2.83x10.75 inch
Dimensions (WxHxD)
3.38kg
Weight
Note: The specifications are subject to change without notice.
Certified UL 458
(Only for “GFCI” receptacles)
Certified EN 60950-1
----
Safety Standards
Certified FCC class B
Certified EN 55022 class B;
EN 61000-3-2, -3-3, -6-3;
EN 61204-3
EMI Conduction &
Radiation
----
Certified EN 61204-3; EN55024;
EN 61000-6-1; ENV 50204;
IEC 61000-4-2, 3, 4, 5, 6, 8, 11
EMS Immunity
Overload, Short Circuit, Reverse Polarity (Fuse),
Over / Under Input Voltage, Over Temperature.
24V
48V
12V
24V
48V
90%
92%
94%
90%
93%
Input Voltage Range
10.5~15.0 VDC 21.0~30.0 VDC 42.0~60.0 VDC
42.0~60.0 VDC
21.0~30.0 VDC
10.5~15.0 VDC
220 / 230 / 240 VAC ± 3%
100 / 110 / 120 V RMS -10% / +4%
220 / 230 / 240 V RMS -10% / +4%
GFCI / NEMA
Schuko
/ Australia / UK / Universal