1.User’s Guide For CR8 Remote Controller   

1-1. Features

Remote ON/OFF inverter operation 
Ignition lockout information display and Return Override Function Acting 

1-2. Specification: 

Input Voltage Range: 10.5 – 60 Vdc depends on Inverter model. 
Operating Temperature Range : 0 – 40 

Storage Temperature Range : - 30 

 -    70 

Stand-By Current Draw : < 40mA 
Applicable Models : ST / SK / SD / SE

 

series 

1-3. Introduction

● 

  This is a simple ON / OFF remote control. 

 

Steady red LED light in dicates the Inverter is ON. 

    Fast flashing red LED light indicates that it is in Return Override Function selection status. 

    Slow flashing red LED light indicates that it is in Ignition Lockout Function selection status. 

● 

   The wire JP1 is placed inside the remote controller and it is to indicate either 

Return Override 

Function

or

Ignition Lockout Function

.

    JP1 jumper “Open” – 

Return Override Function 

    JP1 jumper “Short” – 

Ignition Lockout Function 

Please note that the default mode is OPEN. 

● 

   The wire must go with a 12 Volt 0.5A fuse with proper sizes. 

● 

   Connect the wire RJ-11 to the remote port in front of the panel. 

Ignition Lockout function

 – The Ignition lockout function is to turn the Inverter OFF when   

the auxiliary input wiring is connected to the ACC. (accessory), and 12 Volts is applied. 

Return Override Function 

– The 

Return Override Function 

is to turn the Inverter ON when   

the auxiliary input wiring is connected to the reverse gear Shift, and 12 Volts is applied. 

● 

Installation Procedure

1. Refer to the drawing (see Figure 1) for screw hole and cutout dimensions. 
2.Use the cable between CR8 remote and the inverter. 
3.Switch the inverter to REMO position. 

Inverting

R.O.F Acting

Ignition 

INVERTER REMOTE

Blinking Fast
Blinking Slow

Solid Red

ON/OFF

PUSH

Inverter    Status

(INTERNAL)

PIN
JUMPER

TO

INVERTER

AUX. +12V