Fault handling
Fault
No working
Weak suction
Possibilities
Method
•No power
•Overheat protector
•Failure switch
•Full dust cup
•Full dust on the filter
set
•Block in the brush or
tube
•Shortage of charging
time
•Aging battery
Short using
time after
charging
•Charge the machine
•Restart the machine after cooling
•After-sales repair
•Empty the dust cup
•Clean or change the filter set
•Clean the dust in the brush
•Fully charge the machine
according to the instructions
•Battery is quick-worn part,
please buy a new one for
replacement
Specifications
Rated voltage
Rated power
Battery capacity
Rated voltage for the charger
Output of the charger
Dust cup capacity
Charging time
Working time
11.1V
100W
2000mAh
100-240V~ 50/60Hz
14V, 500mA
0.5 L
4~5h
13~25min