B 217 - RTE 98.  Eng.  

25.09.07 LB   

REV. 01

We reserve the right to make changes without notice

COSTER

B 217

25.09.07 LB

REV. 01

WEATHER COMPENSATOR 

FOR CONTROL OF VALVE OR BURNER

RTE 98.  

Eng.

• Analogue controller for boiler plant:

– 1 modulating or On-Off output for control valve or burner

– 1 On-Off output for control pump or burner in relation to programmed times

– voltage-free output contacts

– adjustment of heating curve to compensate for weather variations in intermediate seasons

– possibility of adjusting value of desired ambient temperature by remote control

• Power supply 230 V~; installation on 144 x 144 control panel back plate
1. APPLICATION

RTE 98. controller is designed for winter compensated control in medium and large central heating plants for 

premises such as:

– administrative and commercial centres

– schools and public buildings

– apartment blocks

 

It is suitable for all climatic zones and for any type of heating media:

 

 

– panels

 

 

– radiators

 

 

– fan coils

RTE 98. controls mixing or diverting valves operated by reversible electric actuators with three-wire control and 

opening times of from 90 to 630 seconds, or the boiler burner.

2. FUNCTIONS

The main functions of RTE 98. are:

• Winter regulation of the flow temperature in relation to the outside temperature with:

– PI control action

– adjustment of heating curve to compensate for weather variations in intermediate seasons 

• Modulating three-wire control or On-Off

• Control plant pump from timed programme in use

• Timed programming: 24-hour (RTE 982) or 7-day (RTE 983)

• Remote control for adjusting temperature programmed on controller

• Timed control : RTE 98 is able to control an On-Off output which operates with the program times used. It can be 

used for the control of the plant circulation pump : in the Normal "Sun" periods contacts 8-10 are closed, while in 

the Setback "Moon" periods contacts 8-10 are open.

4. DETECTORS & ACCESSORIES

  No. 

Description 

Type 

Sensing element  Code  Data sheet

  No. 

Description 

Type 

Sensing element  Code  Data sheet

 

 

E

SSENTIAL

 

ACCESSORIES

:

 

 

E

SSENTIAL

 

ACCESSORIES

:

 

1  

Surface plant flow temperature detector 

 

1  

Surface plant flow temperature detector 

SCH 010

 

NTC 10 k

 

B1 

N 130

 

 

or immersion 

 

 

or immersion 

SIH 010

 

NTC 10 k

 

B1 

N 140

 

1  

Outside temperature detector 

 

1  

Outside temperature detector 

SAE 001

 

NTC 1 k

 

B2 

N 120

 

 

O

PTIONAL

 

ACCESSORIES

:

 

 

O

PTIONAL

 

ACCESSORIES

:

 

Remote control 

 

Remote control 

CDB 340

 

– 

N 711

  No. 

Description 

Type 

Sensing element  Code  Data sheet

 

 

E

SSENTIAL

 

ACCESSORIES

:

 

1  

Surface plant flow temperature detector 

 

 

or immersion 

 

1  

Outside temperature detector 

 

 

O

PTIONAL

 

ACCESSORIES

:

 

Remote control 

  No. 

Description 

Type 

Sensing element  Code  Data sheet

  No. 

Description 

Type 

Sensing element  Code  Data sheet

 

NTC 10 k

 

NTC 10 k

 

NTC 1 k

 

– 

N 711

  No. 

Description 

Type 

Sensing element  Code  Data sheet

 

B1 

N 130

 

B1 

N 140

 

B2 

N 120

 

– 

N 711

  No. 

Description 

Type 

Sensing element  Code  Data sheet

 

B1 

N 130

 

B1 

N 140

 

B2 

N 120

 

– 

N 711

3. VERSIONS

 

Code 

Description

RTE 982

Compensating controller with 24-hour time switch

RTE 983 

  

Compensating controller with 7-day time switch

 

Code 

Description

 

Code 

Description

  

Compensating controller with 7-day time switch

Time switch: 

– power reserve 

100 h

– dial 

4-hour or 7-day

– minimum daily interval 

15 min.

– minimum weekly interval 

24 h

Suitable actuators 

90...630 s

Room temperature: 

– operating 

0...+45 °C

– storage 

– 25...+60 °C

Room humidity 

Class F (DIN 40040)

Protection 

IP 40

Weight 

1.2 Kg

5. TECHNICAL DATA

Power supply 

 

230 V~± 10%

Frequency 

50...60 Hz

Consumption 

 

4 VA

Electromagnetic compatibility 

CEE 93/68

Output contacts: 

– maximum switched voltage 

250 V~

– maximum switched current 

5 (1) A

Setting ranges: 

– Normal and Setback ambient temperature 

0...30 °C

– K factor 

0.5...3.5

– adjustment C curve 

 

± 5 °C

Summary of Contents for RTE 982

Page 1: ...culation pump in the Normal Sun periods contacts 8 10 are closed while in the Setback Moon periods contacts 8 10 are open 4 DETECTORS ACCESSORIES No Description Type Sensing element Code Datasheet No Description Type Sensing element Code Datasheet ESSENTIAL ACCESSORIES ESSENTIAL ACCESSORIES 1 Surface plant flow temperature detector 1 Surface plant flow temperature detector SCH 010 NTC 10 kΩ B1 N 1...

Page 2: ...tback temperature 4 Power supply LED 8 Normal temperature 1 2 4 7 3 5 6 8 8 ACTUATORS SPEED PROGRAMMER 9 WIRING DIAGRAMS B1 Flow detector E Burner Y Valve B2 Outside detector M Plant pump T Transformer R Remote control General layout Control of actuator Control with voltage other than 230 V burner 2 3 Y Co Op Cl L N 230 V 5 6 7 T 2 3 L N 230 V 6 7 In series with boiler thermoistats E 5 6 7 F RTE 9...

Page 3: ...nd secure it Make the electrical connections according to the wiring diagram and in respect of the safety regulations in force using the following cable types 1 5 mm2 for power supply and the relay control outputs 1 mm2 for the detectors and the remote control Apply power 230 V and check its presence across terminals 2 and 3 Switch off power insert the electronic module in the case pressing it as ...

Page 4: ... and the actual time of day and the day on the 7 day one Adjust if necessary the slope of the heating curve using the potentiometer C COSTER TECNOLOGIE ELETTRONICHE S p A Sede Legale 20132 Milano Via San G B De La Salle 4 a E mail info coster eu Web www coster eu COSTER CONTROLLI TEMPERATURA ENERGIA Head Office Sales Via San G B De La Salle 4 a Tel 39 022722121 20132 Milano Fax 39 022593645 Orders ...

Reviews: