background image

4.3 Browsing Video

   

To ensure the real-time video can be played properly, you must 

perform the following operation when you log in the web for the first time:

              

Figure

 

4

-

3

 

Adding

 

a trusted site

Step 2

 

In

 

the Internet Explorer, choose 

Tool

 > 

Internet Options

 > 

Security

 > 

Customer level

, and set 

Download unsigned 

ActiveX control

 and

 initialize and script ActiveX controls not 

marked as safe for scripting under ActiveX controls and 
plug-ins to Enable

, as shown in figure 4-4.

Step 3 Download and install the player control as prompted.

If the repair tips displayed when installing the control , please 
ignore the prompt, and continue the installation, the login page is 
displayed when the control is loaded.

Step

 

1

 

the Internet Explorer. 

Choose Tools

 >

 Internet options

 >

 

Security

 > 

Trusted sites

 > 

Sites

, in

 

the

 

display

 

dialog

 

box

click

 

Add

as

 

shown

 

in

 

figure

 

4

-

3

.

   

To browse a real-time video, click Live Video. The Live Video 

page is displayed

 in figure 4-5.

, as shown

4.4

 

Two-way

 

a

udio

Partial camera do

 

not

 

support two-way

 

a

udio

this section do not 

apply.

Figure

 

4

-

5

 

Live

 

Video

Figure 4

-

4

 

Configuring ActiveX control and plug-in

Component

Hazardous Substance or Element

 

Plumbum 

(Pb)

 

Mercury

 (Hg)

Cadmium

 (Cd)

 

Hexavalent 

Chromium

 (Cr6+)

Polybromina-
ted Biphenyls 

(PBB)

Structural 
part

Board/
circuit 
module

Cable 
connector

Accessor-
ies

: indicates that the concentration of the hazardous substance in 

all homogeneous substances of the component is within the 
limit specified in SJ/T 11363-2006 Requirements for 
Concentration Limits for Certain Hazardous Substances in 
Electronic Information Products. 

×

: indicates that the concentration of the hazardous substance in 

at least one homogeneous substance of the component 
exceeds the limit specified in SJ/T 11363-2006 
Requirements for Concentration Limits for Certain 
Hazardous Substances in Electronic Information Products.

×

×

×

×

Step

 

5 Install the dome shell, the dome shell fixed base and the 

compression ring on the mounting base, as shown in figure 
3-3.

Stream

Camera

Live Video

Playback

Configuration

Polybrominated
Diphenyl Ethers
 (PBDE)

NOTE

NOTE

NOTE

4.4.1 

Camera        PC

       

Connection

Step

 1  

Connect microphone to  audio input interface

 

of camera.

Step

 2  

Connect speaker to the PC audio output interface

.

Step

 3  

Log in camera Web, click     to turn on 

.

4

.

4.2 PC

two-way

 

a

udio

         

Camera

Step1  Connect microphone to PC audio input  interface.
Step2  Connect speaker to camera audio out interface.
Step3  Log in camera Web, click     to turn on 

two-way

 

a

udio

Step 6 Turn the main body, adjust the position so that the camera 

faces the monitored area, then tighten the compression 
ring and fix the camera, as shown in figure 3-4.

Figure 3-4

 Adjusting camera

4.1 

Login

Step 

Open the Internet Explorer, enter the IP address of IP camera 

(default value: 

192.168.0.120)

 in the address box, and press 

Enter. The login page is displayed. as 

figure 

4-1 

.

Step 

Input the user name and password.

shown in 

Ÿ

 

The default user name is admin. The default password is admin. 

Change the password when you log in the system for first time to ensure 
system security.

 

You can change the system display language on the login page.

NOTE

Step3

 

Click Login, the main page is displayed.

Device >

IP 

address to log in the 

4.2 

Modify IP address

   Choose 

Configuration > 

 Local Network

, the 

Local 

Network

 page is displayed.

   Enter the IP address in the IP Address box and click 

Apply

 as shown 

in figure 4-2.

   

After

 

the

 

success

 

of

 

the

 

IP

 

address setting, please use the new 

Web interface.

Figure

 

4

-

2

 

Local

 

Network

User Name

Password

English

Figure

 

4

-

1

 

Login

Local Network 

IP Protocol

DHCP

IP Address

Subnet Mask

Default Gateway

Preferred DNS Server

Alternate DNS Server

MTU(800-1500)

Refresh

Apply

70

Figure 3-1

of 

 

Dimensions 

                    mounting base

70

Outlet

F

igure

 

3

-

Cut the compression

                     ring outlet

 

Mounting base

Compression ring

Dome shell fixed base

Dome shell

F

igure

 

3

-

3

 

 camera installation

Triaxial rotation

Foucs

Zoom

F

igure

3-

5

 

A

djusting view angle and focal length

NOTE

Adjust the position of the camera by triaxial rotation: rotating 
horizontally, rotating up and down, and performing lens axial 
rotation, and adjust the camera direction and lens alignment 
target.

Step 7 Adjust view angle and focal length by using an adjusting 

tool, as shown in figure 3-5.

Appendix

Hazardous Substance Declaration

5

Quick Configuration(e.g IE)

4

Reviews: