Costar 9SIR Owner'S Manual Download Page 3

Instruction Manual: COSTAR

®

 9SIR, Residential CO Alarm 

QGI P/N 099-0057-01 REV 10/26/01 

Page 3 of 7 

3.3 

This CO alarm is designed for use within a single residential living unit only.  In a multi-family building, the alarm 

may not provide early warning for residents if it is placed outside of the residential units, such as on outside porches, in 
corridors, lobbies, basements, or in other apartments. In multi-family buildings, each residential unit should have detectors 
installed as previously indicated. 
3.4 

When properly located, installed, and maintained, this CO alarm is designed to provide early warning of 

developing poisonous CO conditions at a reasonable cost. This alarm monitors the air, and when it senses CO, it activates 
its built-in alarm. It can provide precious time for you and your family to escape from your residence before CO can 
seriously injure or kill.  However, such an early warning is possible only if the alarm is located, installed, and maintained as 
specified in the Owner's Manual.   
 

4.0 

IMPORTANT: WHAT YOUR CO ALARM CAN AND CANNOT DO 

If bedroom doors are usually closed at night, alarms should be placed in each bedroom as well as in the common hallway 
between them.  CO alarms may not sense CO on a different level of a residence or building.  For example, a second floor 
alarm may not sense a CO leak on the first floor or in the basement.   
Therefore, alarms should be placed on every level of a residence or building.  If the alarm is located outside of a bedroom, 
it may not wake up a sound sleeper, especially if the bedroom door is closed or only partly open. If the alarm is located on a 
different level of the residence than the bedrooms, it is even less likely to wake up people sleeping in the bedroom.  
Installing CO alarms may qualify you for lower homeowner's insurance rates, but CO alarms are not a substitute for 
insurance.  Homeowners and renters should continue to insure their lives and property. 

!  WARNING:

 The COSTAR

®

 Model 9SIR CO Alarm is not designed for marine or RV use. 

 

5.0 

INSTALLING THE COSTAR

®

 9SIR FOR RESIDENTIAL USE  

5.1 RECOMMENDATIONS 
 

One of the most important considerations in any CO alarm system is the location of the alarms.  Statistics of the 

National Fire Protection Association (NFPA) show that most of the fatal CO occurrences happen at night while people are 
sleeping.  Early warning of CO is best achieved by the correct installation of CO alarms.  Placement of an alarm in a garage 
may cause an alarm due to CO from automotive exhaust. 
5.2 

RECOMMENDED MOUNTING LOCATIONS  

 

Put a CO alarm inside each bedroom where the occupant closes the door while sleeping.  A closed door can block 

particulate smoke, but CO gas is likely to get through. 
 

 

Figure 1:

  Recommended CO alarm placement for single 

floor residence. 

 

Figure 2:

  Recommended CO alarm placement for multi-

level residence. 

 
5.3 

This CO alarm must be mounted on the wall or ceiling. 

5.4 

WALL LOCATION: Locate the top of the alarm at least 3 feet (usually 5 to 6) feet from the floor.  

 

 

Figure 3:

  Recommended CO alarm mounting location is 5 to 6 feet from floor. 

Summary of Contents for 9SIR

Page 1: ...hown to cause brain and other vital organ damage in unborn infants with no effect on the mother The following symptoms are related to CARBON MONOXIDE POISONING and should be discussed with ALL members of the household MILD EXPOSURE Slight headache nausea vomiting fatigue often described as flu like symptoms MEDIUM EXPOSURE Severe throbbing headache drowsiness confusion fast heart rate EXTREME EXPO...

Page 2: ...larm will automatically sense when the level of CO in the air falls below the danger level You should stay outside the residence in fresh air until the alarm is silenced When the alarm sounds do not stand too close to the alarm The sound produced by the alarm is loud because it is designed to awaken a person in an emergency Prolonged exposure to the alarm at a close distance may be harmful to your...

Page 3: ...e or building If the alarm is located outside of a bedroom it may not wake up a sound sleeper especially if the bedroom door is closed or only partly open If the alarm is located on a different level of the residence than the bedrooms it is even less likely to wake up people sleeping in the bedroom Installing CO alarms may qualify you for lower homeowner s insurance rates but CO alarms are not a s...

Page 4: ...bient conditions such as i Wind direction and or velocity including high gusts of wind Heavy air in the vent pipes cold humid air with extended periods between cycles ii Negative pressure differential resulting from the use of exhaust fans iii Simultaneous operation of several fuel burning appliances competing for limited internal air iv Vent pipe connections vibrating loose from clothes dryers fu...

Page 5: ...pliers Using the long nose pliers pull the pin out of the hole it is now possible to remove the alarm from the mounting plate 6 8 Test alarm immediately following installation and weekly for proper operation by pushing the test button until a short beep is heard approximately three seconds Release the button The alarm will then test itself for proper operation and the RED L E D will flash 4 6 time...

Page 6: ...r one year under normal operating conditions 9 3 USE ONLY THE FOLLOWING 9 VOLT BATTERY FOR CO ALARM REPLACEMENT Alkaline type DURACELL MN1604 WARNING USE ONLY THE BATTERY SPECIFIED USE OF DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL EFFECT ON THE CO ALARM CONSTANT EXPOSURES TO HIGH OR LOW TEMPERATURES OR HIGH HUMIDITY MAY REDUCE BATTERY LIFE CHECK THE BATTERY MANUFACTURERS SPECIFICATIONS FOR PROPER ...

Page 7: ...N LONGER THAN THAT OF THIS WRITTEN WARRANTY EXCEPT AS REQUIRED BY LAW INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR AGAINST INFRINGEMENT OR ANY EXPRESS OR IMPLIED WARRANTY ARISING OUT OF TRADE USAGE OR OUT OF A COURSE OF DEALING OR COURSE OF PERFORMANCE Quantum Group Inc has not authorized any other party to extend any other warranties in conne...