ELECTRICAL REQUIREMENTS
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove the ground prong from the power cord plug.
Do not use an adapter.
Do not use an extension cord.
Failure to do so can result in death, fire or electrical shock.
IMPORTANT:
The range must be electrically grounded in accordance with local
codes and ordinances, or in the absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
This range is equipped with an electronic ignition system that will not operate if
plugged into an outlet that is not properly polarized.
If codes permit and a separate ground wire is used, it is recommended that a
qualified electrical installer determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
•
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-
delay fuse or circuit breaker is also recommended. It is recommended that a
separate circuit serving only this range be provided.
•
Electronic ignition systems operate within wide voltage limits, but proper
grounding and polarity are necessary. Check that the outlet provides 120-volt
power and is correctly grounded.
•
This gas range is not required to be plugged into a GFCI (Ground-Fault Circuit
Interrupter) outlet. It is recommended that you not plug an electric spark
ignition gas range or any other major appliance into a GFCI wall outlet as it may
cause the GFCI to trip during normal cycling.
•
Performance of this range will not be affected if operated on a GFCI-protected
circuit. However, occasional nuisance tripping of the GFCI breaker is possible
due to the normal operating nature of electronic gas ranges.
•
The wiring diagram is located on the back of the range in a clear plastic bag.
9