Gebruiks- en montagehandleiding Cosiloft / Operating and assembly instructions Cosiloft / manuel de montage et mode démploi Cosiloft
2.
The supplied hose is 1.5 m long . Place the gas bottle at a maximum distance of 1 meter from the
Cosiloft. Be carefull by placing the gashose, people and pets can stumble over it. Indeed place the
cylinder therefore always at a place where walking along is not possible and where children and
pets cannot reach.
3.
Connect the gasbottle to the supplied pressure regulator and turn the bottle open if you want to
use. When you are not using the Cosiloft make sure the gas valve on the gas bottle is turned off.
3. Replacing the cylinder
Is the gas bottle empty and you need to replace it? Make sure the model, ceramic logs and lava rocks are
completely cooled down! Use the definition of point 2 “placing the gas bottle” and remove the old bottle. You
can fill up the old bottle at the local gas supplier.
4. Replacing the hose and pressure regulator
Replace your propane gas hose every four years . This is a national advice. Pressure regulators can go for five
years. Always check the unit after replacing the pressure regulator and gas hose for gas leaks .
How to check your Cosiloft on gas leaks:
-
Open the gas bottle but do not turn on the Cosiloft!
-
Make a spray of half water and half of detergent, and spray this liquid on each connection and the hose.
If there is a gas leak in the connection or the hose there will be air bubbles arise.
-
If bubbles are visible, immediately shut off the gas. Buy a new hose or regulator.
-
If the problem persist, please contact a qualified gas engineer.
Replace the hose or pressure regulator so that they are mounted on the exact same way. In the Netherlands, a
30 mbar pressure regulator should be placed. The hose must not be longer that 2.5 meters.
When in doubt, always consult a qualified gas engineer .
5. Replacing the battery for the piezo ignitior
The Cosiloft features a piezo ignition that runs on one AA battery . It may happen that after repeated use , the
battery runs out . The battery can be replaced as follows :
-
Make sure the model, ceramic logs and lava rocks are completely cooled down.
-
Make sure the Cosiloft is no longer connected to the gas cylinder.
-
On the control panel, there is the ignitor, the battery is in the black capsule.
-
You can now rotate the black ignition and open the battery as instructed in the sites of inflammation
-
The old battery should be returned to a collection point .
5.
Moving the unit
It is advisable to minimize the move with Cosiloft. With every move you risk to damage the Cosiloft. If
you still want to move the unit , make sure that the Cosiloft is locked off from the gas bottle. The new
location for Cosiloft needs to be clean, flat and hardened again.
7. Installing the cover
At each Cosiloft is a protective cover supplied. The protective cover protects your Cosiloft against