Ambient temperature around each power supply should not ex-

ceed the temperature range shown in the derating curve.

¿ 

PLA300F

F
A
N

Air flow

Terminal block

side

Vent hole 

side

Fan side

More than

30mm

More than

30mm

More than

30mm

Terminal block

Terminal block

(A)

Vent hole 

side

More than

30mm

Terminal block

Terminal block

(B)

(C)

(D)

(E)

Terminal block

Not available

¿ 

PLA600F

F
A
N

Air flow

Terminal block

side

Fan side

More than

30mm

More than

30mm

More than

30mm

Terminal 

block

Terminal block

(A)

Vent hole 

side

Vent hole 

side

More than

30mm

Terminal block

side

Terminal block

(B)

(C)

(D)

(E)

Terminal block

Not available

¡

Avoid installation method (E), which can cause stress on the 

mounting holes.

¡

Fan for forced cooling is built-in.  Do not block the ventilation at 

suction side (terminal block and vent hole side) and its opposite 

side.

¡

When unit operates at dusty place, attach air-fi lter to dust into the 

unit.  In this case, avoid poorly ventilated environments.

¡

When internal fan stops, thermal protection circuit works which 

stops the output.  To keep reliability of the unit, periodic mainte-

nance of the fan is required.

¡

Expected life of fan (R(t) = 90%) is different by the used condition.

2.2 Parallel Operation

¡

Redundancy operation is available by wiring as shown below.

I

2

I

1

I

3

-

+

+

-

Load

Power
Supply

Power
Supply

Fig.2.2  Example of redundancy operation

¡

Even a slight difference in output voltage can affect the balance 

between the values of I

1

 and I

2

.

Please make sure that the value of l

does not exceed the rated 

current of a power supply.

l

3

 

[

 the rated current value

¿ 

PLA100F, PLA150F, PLA300F

¡

Parallel operation is not possible.

¿ 

PLA600F

¡

Available by option -W. Please refer to instruction manual “5. Op-

tion and Others”.

3  

Assembling and 
Installation Method

3.1 Installation Method

¡

Do not insert a screw more than 6mm away from the outside of 

a power supply to keep enough insulation distance between the 

screw and internal components.

6mm max

Chassis of
 PBA series

Chassis of 
customer system

Mounting Screw

PLA series

Fig.3.1 Mounting screw

¿ 

PLA100F, PLA150F

(A)

(B)

(C)

Terminal block

Terminal block

More than
20mm

¡

If you use two or more power supplies side by side, please keep 

a suffi cient distance between them to allow enough air ventilation. 

AC-DC Power Supplies Enclosed type

Instruction Manual

PLA-14

PLA

me̲pla1.indd   PLA-14

me pla1 indd PLA-14

2014/03/04   10:34:43

2014/03/04 10:34:43

Summary of Contents for PLA100F

Page 1: ...ted input fuse Inrush current protection circuit PCB Pattern Series Parallel operation availability Material Single sided Double sided Series operation Parallel operation PLA100F Active filter 40 to 1...

Page 2: ...on 1 4 Overvoltage Protection 1 5 Thermal Protection 1 6 Output Ripple and Ripple Noise 1 7 Output Voltage Adjustment 1 8 Isolation 1 9 Low Power Consumption 1 10 Remote ON OFF 1 11 Remote Sensing 1 1...

Page 3: ...imary inrush cur rent and secondary inrush current will be generated because the thyristor technique is used for the inrush current limiting circuit 1 3 Overcurrent Protection An overcurrent protectio...

Page 4: ...ial probe C1 Film capacitor 0 1 F C2 Aluminum electrolytic capacitor 22 F Fig 1 2 Measuring method of Ripple and Ripple Noise Remarks When GND cable of probe with flux of magnetic force from power sup...

Page 5: ...ility of the unit periodic mainte nance of the fan is required Expected life of fan R t 90 is different by the used condition 2 2 Parallel Operation Redundancy operation is available by wiring as show...

Page 6: ...Forced air 0 5m3 min 1Convection A mount 2Convection B C mount 0 8 0 10 0 6 0 4 0 5 0 2 20 10 Load factor C Ambient temperature Fig 3 3 Ambient temperature derating curve for PLA100F 150F 12 15 20 10...

Page 7: ...e of fan AIR FLOW 20mm Measurement point Power supply Terminal block F A N Side AIR FLOW 20mm Measurement point Power supply Terminal block F A N Top Fig 3 8 Temperature of measurment point for fan li...

Page 8: ...0F You can control output ON OFF in Option R units An external DC power supply is connected and it should be applied a volt age to a remote ON OFF connector to control it Appearance is changed from st...

Page 9: ...ard model There is a lineup of optional harnesses Refer to option parts Please contact us for details Differences from standard versions are summarized in Table 5 6 Table 5 7 Specification differences...

Page 10: ...on the model and the number of parallel operation Please contact us When output cable is not same length from each power supplies output current value will not be balanced at each units Please set the...

Page 11: ...Please do not apply more than 5A per 1 pin Option J can not meet UL508 V ADJ AC L AC N FG V V CN1 CN2 Fig 5 15 Example of option J PLA100F Table 5 11 Mating connectors and terminals on CN1 and CN2 in...

Page 12: ...e turning on the electricity and for a while after turning off please don t touch the inside of a power supply because there are some hot parts in that When a mass capacitor is connected with the outp...

Reviews: