Derating curve depending on input voltage
Derating curve depending on input voltage is shown in Fig.3.14.
¿
LGA100A-
O
-SN (with Chassis & Cover)
¿
LGA150A
¿
LGA150A-
O
-SN (with Chassis & Cover)
¿
LGA240A
¿
LGA240A-
O
-SN (with Chassis & Cover)
¡
Mounting method
*
(F) mounting should be operated by Forced air.
¡
The guideline for air cooling
It shows the upper temperatures of Point A and B on Table 3.1 to
Table 3.6.
Please take care to keep those temperatures below the points of
the tables by air convection.
And please be attentive to keep that the entire power supply is
well ventilated.
At the upper temperatures of Point A and Point B (refer to External
View) on Table 3.1 to Table 3.6, the expectancy life is 3 years or more.
In case of with Chassis and Cover, please contact our sales offi ce
for getting more information.
Remarks:
*
Please be careful of electric shock or earth leakage in case of
temperature measurement, because Point A and Point B is live
potential.
*
Please refer to 3.4 if you want to extend the longevity of the ex-
pectancy life.
-10
60
50
40
30
2
2
Forced air (0.5m
3
/ min)
1
Convection
80
100
60
40
20
0
10
20
0
Load
factor
[%
]
[
C
]
Ambient temperature
(A) ~ (F)
mounting
1
1
(A)mounting
1
(B), (C)mounting
(D)mounting
1
(E)mounting
AC-DC Power Supplies Open Frame/ Enclosed Type
Instruction Manual
LGA-16
LGA
*
[F] mounting should be operated by Forced air.
Fig.3.14 Derating curve depending on input voltage
Fig.3.9 Ambient temperature derating curve
*
[F] mounting should be operated by Forced air.
Fig.3.10 Ambient temperature derating curve
*
[F] mounting should be operated by Forced air.
Fig.3.11 Ambient temperature derating curve
*
[F] mounting should be operated by Forced air.
Fig.3.12 Ambient temperature derating curve
*
[F] mounting should be operated by Forced air.
Fig.3.13 Ambient temperature derating curve
-10
60
50
40
30
1
2
2
Forced air (0.5m
3
/ min)
1
Convection
80
100
60
40
20
0
10
20
0
Load
factor
[%]
[
C
]
Ambient temperature
(D), (E)mounting
(A) ~ (F)
mounting
1
1
(A)mounting
(B), (C)mounting
[AC V]
[%]
100
80
85 90
Load factor
Fig.3.15 Mounting method
-10
70
60
50
40
30
2
2
1
Convection
80
100
60
40
20
0
20
10
0
Load
factor
[%
]
[
C
]
Ambient temperature
(A) ~ (F)
mounting
Forced air (0.5m
3
/ min)
1
1
(B)mounting
(E)mounting
1
1
(A)mounting
(C), (D)mounting
(D)
(E)
(F)
CN1
CN1
CN1
Standard
Position
CN1
(A)
(B)
(C)
CN1
CN1
-10
60
50
40
30
2
2
Forced air (0.5m
3
/ min)
1
Convection
80
100
60
40
20
0
10
20
0
Load
factor
[%
]
[
C
]
Ambient temperature
(A) ~ (F)
mounting
1
1
(A)mounting
1
(B), (C)mounting
(D)mounting
1
(E)mounting
-10
60
50
40
30
1
2
2
Forced air (0.5m
3
/ min)
1
Convection
80
10
95
0
60
40
20
0
10
20
0
Load
factor
[%]
[
C
]
Ambient temperature
(D), (E)mounting
(A) ~ (F)
mounting
1
1
(A)mounting
(B), (C)mounting
me̲lga1.indd LGA-16
me lga1 indd LGA-16
2015/06/19 14:42:26
2015/06/19 14:42:26