The communication wires and power line should NOT be bound in the same conduit or tubing.

Don’t equip reader and lock with the same power supply. The power for reader may be unstable when the lock is activating, that may make the 

reader malfunction.

The standard installation: Door relay and lock use the same power supply, and reader use independent power supply.

Use AWG 22-24 Shielded Twist Pair to avoid star wiring ,CAT 5 cable for TCP/IP connection

1.Tubing:

2.Wire selection:

3.Power supply:

1

Products

3

Terminal Cables

4

Tools

Notice

Connector Table (1)

5

Optional

Wire Application

Wire

Color

Description

Lock Relay

1

Blue White (N.O.)DC24V1Amp

2

Purple White (N.C.)DC24V1Amp

Lock Relay COM

3

White

(COM)DC24V1Amp

Door Contact

4

Orange

Negative Trigger Input

Exit Switch

5

Purple

Negative Trigger Input

Alarm Relay

6

Gray

Transistor Output Max. 12V/100mA 

(Open Collector Active Low)

Power

7

Thick Red DC 12V

8

Thick Black DC 0V

Cable:

P1

Wire Application

Wire

Color

Description

RS-485 for Lift

Controller

1

Thick Green RS-485(B-)

2

Thick Blue RS-485(A+)

Cable:

P4

Wire Application

Wire

Color

Description

1

---

---

2

---

---

TCP/IP Output

3

Orange White Net - TX+

4

Orange

Net - TX-

5

Green White Net - RX+

6

Green

Net - RX-

7

---

---

P3

Cable:

Wire Application

Wire

Color

Description

Beeper

1

Pink

Beeper Output 5V/100mA, Low

LED

2

Yellow

Red LED Output 5V/20mA, Max

3

Brown

Green LED Output 5V/20mA, Max

Door Output

4

Blue White Transistor Output Max. 12V/100mA 

(Open Collector Active Low)

Wiegand

5

Thin Green Wiegand DAT: 0 Input

6

Thin Blue Wiegand DAT: 1 Input

WG Door Contact

7

Orange

Negative Trigger Input

WG  Exit Switch

8

Purple

Negative Trigger Input

P2

Cable:

Use a screwdriver to screw the mounting plate to the wall.
Pull cables ends through the access hole in the mounting plate. 
Attach ACC995-V2 to the mounting plate and install screws (supplied) into the holes at the 
bottom with the allen key. 
Apply power. LED (green) will light up with one beep.

Installation

ECL-ACC995-V2

Summary of Contents for COR-ACC995-V2

Page 1: ...igger Input Alarm Relay 6 Gray Transistor Output Max 12V 100mA Open Collector Active Low Power 7 Thick Red DC 12V 8 Thick Black DC 0V Cable P1 WireApplication Wire Color Description RS 485 for Lift Controller 1 Thick Green RS 485 B 2 Thick Blue RS 485 A Cable P4 WireApplication Wire Color Description 1 2 TCP IP Output 3 Orange White Net TX 4 Orange Net TX 5 Green White Net RX 6 Green Net RX 7 P3 C...

Page 2: ...incorrect pin code or master code 4 Maximum error in ut of pin code and master code can be changed via the software 701Server default 5 times Power Green Alarm Red Alarm Green OK Green Error Red In processing Green Networking and interactively flash between the Month and DAY e g 12 07 12 07 Stand alone No flashing e g 12 07 Reference to picture Connect to Electric Bolt Wiring Diagram EXIT 1 2 3 4 ...

Page 3: ...TE RTE RTE POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC Electric Strike Door Contact Strengthen security with ACC 899 If any fire emergency the people can escape by press a switch to open all doors Electric Bolt Electric Bolt Electric Bolt Fire Emergency Transistor IN4007 Transistor IN4007 Connect to Reader Magnet Lock Connect to Electric Strike Connect to Do...

Page 4: ...ogramming mode 7 Access programming mode Add Delete Add RF Learn Input 5 digit user address Input Tag Units pcs Close Tag into RF Area If a batch of tags are Sequential input Tag Units pcs in the quantity of the tags and present the tag with the lowest number to the controller 1 2 Adding Tag by RF Learn Function Tag Information SITE CODE CARD CODE SITE CODE CARD CODE User capacity 16384 00000 1638...

Page 5: ... Arming 7 Disable Access programming mode Quit 6 No open the door Input 4 digits arming PWD Present the tag to reader Access programming mode Parameters 1 ArmingDelayTm Enter armed sta Delay time Sec Range 000 255 Armed pulse out put time 10ms Range 000 255 Succeeded 3 7 Use FP can substitute for Induct valid card F Adding Deleting Fingerprint or Finger Vein Adding Access programming mode User Set...

Page 6: ...git user address Input single floor number 1 64 2 4 Single floor Access programming mode User Setting Multi Floor Input 5 digit user address Select range 1 or 2 or 3 or 4 Input 16 digits multi floors number 0 disable 1 enable e g Set NO 114 can use it with the 8 F and 16F Access programming mode User Setting Multi Floor 114 1 0000000100000001 2 2 5 5 Multi floors Set Floor Stop 1 0 17 0 33 0 49 0 ...

Page 7: ...y Tm 7 Arming Delay Tm 8 Arming PWD 2 User Setting 1 Password 2 Access Mode 3 Extend Options 4 Single Floor 5 Multi Floor 6 Enroll Finger 7 Delete Finger 1 Add Delete 1 Add Card ID 2 Add RF Learn 3 Suspend Address 4 Suspend ID 5 Delete Address 6 Delete ID 7 Recover Address 8 Recover ID 9 Antipass Group Reset all device parameters and user card data Access programming mode Parameters2 Factory Reset...

Page 8: ...same as sticker on Ethernet Module device Please revise IP address you want and then click Update button After updating the IP please re connect the Web Browser by new IP address User Password The password composes of 10 characters at most it can be either A Z or 0 9 Change the log in password to lock the IP setting of Ethernet Module If the IP address of ACC995 V2 has changed We must enter the ne...

Reviews: