3.4

 

Handling and Usage 

 

  Stop using this bracelet and consult with your physician if you experience skin 

irritation or discomfort. 
 

  Consult with your physician before using this bracelet on an arm where intravascular 

access or therapy, or an arterio-venous (A-V) shunt, is present because of temporary 
interference to blood flow, which could result in injury. 
 

  Consult with your physician before using this bracelet if you have severe blood flow 

problems or blood disorders.  
 

  DO NOT use this bracelet for any purpose other than measuring heartbeats. 

 

  During measurement, make sure that no mobile device or any other electrical device 

that emits electromagnetic fields is within 12 inches (30 cm) of this bracelet. This may 
result in incorrect operation of the bracelet and/or cause an inaccurate reading. 
 

  DO NOT disassemble or attempt to repair this bracelet or other components. This 

may cause an inaccurate reading. 
 

  DO NOT drop or subject this bracelet to strong shocks or vibrations. 

 

  DO NOT use this bracelet with other medical electrical (ME) equipment 

simultaneously. This may result in incorrect operation of the bracelet and/or cause an 
inaccurate reading. 
 

  Ensure that this bracelet has acclimated to room temperature before taking a 

measurement. Taking a measurement after an extreme temperature change could 
lead to an inaccurate reading.  
 

  Ensure the bracelet is well adjusted on the wrist to have the best performance of the 

heart rate sensor, and not too tight to avoid skin injuries 
 

3.5

 

Charger Handling and Usage 

 

  USE the charger cable with a CE marked adapter with the following characteristics: 

o

  Input voltage: 100/240 V - 50hz 60hz 

o

  Output voltage: DC 5V (+-5%) 

o

  Maximum current: 500 mA 

 

  DO NOT use the charger if this bracelet or the charger cable is damaged. If this 

bracelet or the cable is damaged, unplug the charger immediately. 
 

  Plug the charger into the appropriate USB outlet. DO NOT use in a multi-outlet plug. 

 

  NEVER plug in or unplug the charger from the electric outlet with wet hands. 

 

  DO NOT disassemble or attempt to repair the charger. 

Summary of Contents for CardioWatch 287

Page 1: ...As of 2021 11 23 Revision status 9 1 EN CardioWatch 287 1B Bracelet Instruction Manual...

Page 2: ...rt Device 18 7 4 Troubleshooting the Bluetooth Connection 21 7 5 Troubleshooting the Cloud Connection 22 8 NON MEDICAL INFORMATION 23 9 PREMIUM SERVICE 26 10 PREVENTICUS HEARTBEATS 27 10 1 Purpose 27...

Page 3: ...ensure the safe and proper use of this bracelet READ and UNDERSTAND all of the safety and operating instructions If you do not understand these instructions or have any questions contact support cors...

Page 4: ...oxygen rich environments or near flammable gas Consult with your physician before using this bracelet if you have common arrhythmias such as atrial or ventricular premature beats or atrial fibrillatio...

Page 5: ...ading DO NOT drop or subject this bracelet to strong shocks or vibrations DO NOT use this bracelet with other medical electrical ME equipment simultaneously This may result in incorrect operation of t...

Page 6: ...t pain pressure tightness etc You may be experiencing a cardiac arrhythmia or other disease even in the absence of a notification from the APP You should notify your practitioner at any changes of you...

Page 7: ...11 23 Revision status 9 7 Dry the wrist band with a soft cloth It is not necessary to sterilize the device The Smartwatch is an electronic device with rechargeable battery The expected service life i...

Page 8: ...related to safety Note Indicates the need for the user to consult the instructions for use Applied Part TYPE BF Applied Part IEC 60417 5333 Indicates the manufacturer s catalogue number so the medica...

Page 9: ...As of 2021 11 23 Revision status 9 9 5 CONTENTS PRODUCT INCLUDES Figure 1 Bracelet CS 287 1B Figure 2 Charger CS 287CH 1 Figure 3 Instruction Manual CS 287IFUEN 1...

Page 10: ...BRACELET 6 1 Front of the bracelet A Ambient Temperature Sensor B LEDs C Pusher button Figure 4 Front view of Bracelet 6 2 Back and bottom of the bracelet D Temperature Sensors E PPG Sensor F Magnets...

Page 11: ...cable to the backside of the bracelet The magnets will pull the charger head to the bracelet Figure 7 Charging view charger attached The Magnets will click the charger into position The LEDS will lig...

Page 12: ...en B1 OFF Bracelet fully charged or not on charger Orange B2 Flashing for 5 sec After the pusher is pressed when the Bracelet is looking for the Bluetooth Low Energy connection Orange B2 ON for 5 seco...

Page 13: ...status 9 13 7 USING YOUR BRACELET WITH A SMART DEVICE 7 1 Download and install the free CORSANO app onto your smart device 7 2 First time use Select Sign Up 2 to create your account If you have an acc...

Page 14: ...As of 2021 11 23 Revision status 9 14 Sign Up Enter your Email Address First Name and Last Name Agree to Terms of Service and Privacy Policy Press the Sign Up button...

Page 15: ...As of 2021 11 23 Revision status 9 15 You will receive an email with a link to the confirmation page Please fill your password and confirm password When ready press the Continue button...

Page 16: ...Revision status 9 16 A password should have at least 8 characters at least one letter a b c at least one number and both Upper and Lower case characters Password must NOT contain only numbers or conse...

Page 17: ...As of 2021 11 23 Revision status 9 17 After you have signed up you can Sign In...

Page 18: ...As of 2021 11 23 Revision status 9 18 7 3 Pairing Your Bracelet with a Smart Device Upon first sign in user will be asked to pair a bracelet follow the instructions First select 287 1B in the list...

Page 19: ...21 11 23 Revision status 9 19 Press the pusher the orange LED will flash the bracelet is waiting for pairing Press on button in the app to start pairing After button is pressed app will look for the b...

Page 20: ...ght the orange LED up for 10 seconds and then turn it OFF The app will display the Serial Number found Please double check the S N on the device and click Confirm The devices is now paired to the app...

Page 21: ...n 6 Re open the app If these steps did not reconnect please proceed 1 Shut down your phone do not do restart completely shut the phone off and turn it back on This will fully reset the Bluetooth syste...

Page 22: ...ur phone s Airplane Mode off and on again 4 Re open the app If these steps did not reconnect please proceed 1 Shut down your phone do not do restart completely shut the phone off and turn it back on T...

Page 23: ...As of 2021 11 23 Revision status 9 23 8 NON MEDICAL INFORMATION The CORSANO app provides non medical information like Activity...

Page 24: ...As of 2021 11 23 Revision status 9 24 Sleep...

Page 25: ...As of 2021 11 23 Revision status 9 25 Heart Rate...

Page 26: ...As of 2021 11 23 Revision status 9 26 9 PREMIUM SERVICE The CORSANO app offers Preventicus Heartbeats as a Premium Service User needs to select a plan...

Page 27: ...6 Heart rate is displayed as normal grey traffic light or abnormal orange traffic light based on a 1 minute measurement Three categories are distinguished no abnormalities green traffic light slight a...

Page 28: ...such At the same time the specificity correct negative rate provides the percentage of users not suffering from atrial fibrillation whose results were correctly displayed with a green traffic light Th...

Page 29: ...G signal in a similar way to the medical procedure photoplethysmography The pulse curve corresponds to the blood pulsation resulting from the activity of the heart Based on the variability of the hear...

Page 30: ...with irregular results are marked in the heart rate graph with a yellow or red dot Dots can be tapped to display the json result plus a PDF can subsequently be pulled PDFs will go into an be collected...

Page 31: ...ormal heart rate Yellow Slight arrhythmia 5 of all beats are irregular and or a slightly increased or decreased heart rate Red Absolute arrhythmia with suspected atrial fibrillation and or a significa...

Page 32: ...on 1 contain both baseline data and optional information such as name and comments on the measurement In addition the heart rate and heart rhythm results are made available to you in text form includi...

Page 33: ...ions of the heart rate occur chaotically throughout the entire measurement Fig 8 9 3 Summarised results of the heart rhythm analysis and heart rate in beats per minute bpm over theentire measurement o...

Page 34: ...d disruption which could be caused by movement environmental light or camera readjustments Fig 8 9 5 Original pulse curve of the measurement report with detected disruption blue bar 10 10 Measurement...

Page 35: ...As of 2021 11 23 Revision status 9 35...

Page 36: ...time To do this go to the bin icon Now you can select individual reports in the list that should be deleted In this mode you can cancel your selection at any time by tapping on a new report To cancel...

Page 37: ...e service for a fee The Telecare service offers you a direct medical assessment of your measurements by Telecare employees who specialise in heart rhythm analyses of heart rate data The Telecare servi...

Page 38: ...vice can be found in this section You can also share the detailed view of the Telecare report with others To do this select a Telecare report from the list and go to the detailed view Tap the Share bu...

Page 39: ...e measurement or up to 5 measurement reports Single measurement select Single measurement if you only want to send one report Keep in mind that you can send each report only once Several measurements...

Page 40: ...le Fit apps however doing so will limit the information available in your personal report The CORSANO app shares the following pieces of information with the Apple Health and Google Fit app Heart Rate...

Page 41: ...beat RR interval variations msec 0 200 ms 5 10 sec 1 sec HRV 10 ms MAD 5 MARD at rest Respiration Rate Number of breaths inhalation exhalation cycles per minute breaths minute brpm 5 45 brpm 20 30 sec...

Page 42: ...64 Mbit Recording Continuous Power Requirements Average current 1 mA Max current consumption 45 mA Battery type Rechargeable Technology Lithium Polymer Battery capacity Bracelet 93 mAh Autonomy Brace...

Page 43: ...nt guidance RF emissions CISPR 11 Group 1 The Corsano Bracelet uses RF energy only for its internal function Therefore RF emissions are very low and are not likely to cause any interference in nearby...

Page 44: ...loors are covered with synthetic material the relative humidity should be at least 30 Electrical fast transient burs t IEC 61000 4 5 2 kV for power supply lines 1 kV for input outpu t lines 2 kV for p...

Page 45: ...omagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol Conducted RF IEC 61000 4...

Page 46: ...ications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3...

Page 47: ...DEVICE Once your bracelet has reached its end of life it has to be properly recycled so that the material can be reused and will not end up in the environment Preferably bring your device to a recycli...

Page 48: ...As of 2021 11 23 Revision status 9 48 16 CORSANO CONTACT INFORMATION Corsano Health B V Wilhelmina van Pruisenweg 35 2595 AN The Hague The Netherlands www corsano com...

Page 49: ......

Reviews: