© Corroventa Ltd.
2017.05
15 (17)
4.
Press the tensioning wheel backward
on the rotor unit and slide the belt off
the wheel so that the rotor can rotate
freely.
5.
Note!
Always use a suitable protective
mask when cleaning the rotor and
perform the work in a suitable location
outdoors.
Carefully blow clean the inside of the
rotor using compressed air. Hold the
nozzle about 15 cm from the rotor and
start blowing from the heat shield side
of the rotor. In this way, the air will
flow through the rotor in the opposite
direction to normal. This prevents more
dirt from getting stuck inside.
When you later clean from the other
direction, do not blow air into the heat
shield, otherwise dirt will accumulate
inside. Only blow on the rotor where
the opposite side is free and
unobstructed.
6.
Assemble the drier in reverse order
when the rotor has been cleaned:
•
Install the belt.
•
Carefully lower the rotor unit into
the machine.
•
Reinstall the wet air hose. Reinstall
the bracket on A2ES and reconnect
the hose on the nipple on the heat
shield of the rotor unit.
•
When the cover is in place and its
four screws installed, ensure that
the tag washers, one at each end of
the machine are also installed.