5.3 Electrical connection and start-up
If the ON lamp does not light, make sure the emergency button is not pressed (chapter
5.5). If the
computer and monitor do not come on, make sure the power cables have been properly connected to the
auxiliary sockets, and that the corresponding switches have been turned on..
When the software is launched it offers the operator a series of procedure requests, including initialization
). This operation is strictly related to the type of management software used.
5.4 Initialization
INITIALIZATION
is a preparatory phase that has to be carried out when the machine is turned on.
If the computer is turned off and back on again, initialization is not strictly necessary, even if required by
the software; it is solely at the discretion of the operator.
DANGER
If the Autocap is open, initialization automatically closes it.
If the automatic shelf is at a certain height it will lower completely.
Moreover, initialization must be carried out in the following cases:
•
At the beginning of each work shift, even if only the computer had been shut down.
•
To send new operating parameters set via the management software.
•
After an emergency stop (chapter 5.5).
For more information about the Initialization function, refer to the software user’s manual.