3
SERVICING THE TOOL
Lubrication
Ingersoll--Rand No. 50
For the Gearing --
Ingersoll--Rand No. 28
For the Ratchet Housing
Ingersoll--Rand No. 66
Always use an air line lubricator with these tools.
We recommend the following Filter--Regulator--Lubricator
(FRL) Unit:
For USA use Unit Number C28--04--FKG0--28
For International use Unit Number C28--C4--FKG0
Before starting the tool and after each two or three
hours of operation,
unless the air line lubricator is used,
pour approximately 1.5 cc of Ingersoll--Rand No. 50 Oil
into the air inlet.
Periodically
, inject several drops of Ingersoll--Rand
No. 50 Oil between the Ratchet Housing (29) and Ratchet
Yoke (34) to lubricate the Drive Bushing (33).
(Dwg. TPD905--2)
F
L
R
Main Line(s) Inner Ø
to be 3X Size of
Air Tool’s Inlet Ø
To Air
System
To Air
Tool
Lubricator
Emergency
Shut--Off
Valve
Regulator
Filter
Compressor
FRL
Drain Regularly
Branch Line(s) Inner Ø
to be 2X Size of
Air Tool’s Inlet Ø
SPECIFICATIONS
Model
Drive
Free Speed
Recommended Torque Range
in.
rpm
Ft--lb (Nm)
IR--C107XP
3/8”
160
10 to 45 (14 to 61)