Preparatiss
2-8
Checking the Fiber End Faces
NOTE
Good splicing results can only be obtained with good end face quality.
After inserting the fiber in the fusion splicer and before ignition of the arc, the fiber ends
can be observed on the monitor.
If more time is needed select the menu item “Search fibers?” The fiber ends are moved to
the center of the monitor.
-
If the quality of the endface is poor, especially when the fusion splicer gives out a warn-
ing, the fiber end must be prepared again.
NOTE
As soon as you notice that endface quality is poor, you can interrupt the alignment
operation by activating the
key.
Bad
Good
The fiber ends must be:
•
Clean
•
Free of noses and cracks
•
Flat
•
Perpendicular to the fiber axis