Quick Installation Sheet | CMA-267-AEN | Page 3
Corning Optical Communications
2.
MOUNT CHASSIS IN 19-IN RACK
Notes:
• One HEU supports connections to up to four OIUs
• HEU chassis requires 4U rack height availability
• Rack nuts and screws not provided
Step 1:
Determine the location of the HEU in the rack
while considering additional HEU and OIU units
and the lengths of the available ERFC cable.
Figure 1 and Figure 2 describe the optimal rack
installations for a maximum 4x4 HEU-OIU
configuration in shared and dedicated equipment
scenarios.
Step 2:
Referring to Figure 3, secure the units’ rack ears to
the rack frame as follows:
• Insert two screws halfway into the rack frame.
• Position the chassis on to the screws using the
handles and the top and bottom half slots of
the rack ears.
• Secure the unit in the rack via all applicable
bracket holes using the appropriate rack nuts
and screws.
Figure 1. 4x4 Installation Diagram – Dedicated
Figure 2. 4x4 Installation Diagram – Shared
Figure 3. Installing Chassis in Rack