24 – Corning Lambda EliteTouch Pipettors 

INSTRUCTION MANUAL – 25

For your reference, make a note of the model number, serial 

number, date of purchase, and supplier here.
Model No. 

Serial No. 

Date Purchased 

Supplier

13. Warranty Statement

Corning Incorporated (Corning) warrants that this product 

will be free from defects in material and workmanship for 

a period of three (3) years from date of purchase. CORNING 

DISCLAIMS ALL OTHER WARRANTIES WHETHER EXPRESSED 

OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF 

MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR 

PURPOSE. Corning’s sole obligation shall be to repair or 

replace, at its option, any product or part thereof that 

proves defective in material or workmanship within the 

warranty period, provided the purchaser notifies Corning 

of any such defect. Corning is not liable for any incidental 

or consequential damages, commercial loss or any other 

damages from the use of this product.
This warranty is valid only if the product is used for its 

intended purpose and within the guidelines specified in the 

supplied instructions manual. This warranty does not cover 

damage caused by accident, neglect, misuse, improper 

service, natural forces or other causes not arising from 

defects in the original material workmanship. This warranty 

does not cover the PTFE seal, O-ring, or shaft. Claims for 

transit damage should be filed with the transportation 

carrier.

In the event this product fails within the specified period 

of time because of a defect in material or workmanship, 

contact Corning Customer Service at: USA/Canada 

1.800.492.1110, outside the U.S.+1.978.442.2200, visit 

www.corning.com/lifesciences

, or contact your local 

support office.

Corning Customer Service will help arrange local service 

where available or coordinate a return authorization 

number and shipping instructions. Products received 

without proper authorization will be returned. All items 

returned for service should be sent postage prepaid in 

the original packaging or other suitable carton, padded to 

avoid damage. Corning will not be responsible for damage 

incurred by improper packaging. Corning may elect for 

onsite service for larger equipment.
Some states do not allow limitation on the length of 

implied warranties or exclusion or limitation of incidental 

or consequential damages. This warranty gives you specific 

legal rights. You may have other rights which vary from state 

to state.
No individual may accept for, or on behalf of Corning, any 

other obligation of liability, or extend the period of this 

warranty.

Summary of Contents for Lambda EliteTouch

Page 1: ...Corning Lambda EliteTouch Pipettors Single channel 8 channel and 12 channel Pipettors Instruction Manual...

Page 2: ...6051 0 5 10 20 6052 2 20 50 6053 5 50 100 6054 10 100 200 6055 20 200 1000 6056 100 1000 8 channel and 12 channel Pipettors 8 10 12 10 6057 6061 0 5 10 8 50 12 50 6058 6062 5 50 8 200 12 200 6059 606...

Page 3: ...ector bar in the multi channel pipettors Materials Used Handle parts Polypropylene PP Polycarbonate PC Polyacetal POM Stainless steel Shaft and piston area parts Polypropylene PP Polyvinylidene fluori...

Page 4: ...e the pipettor as it may damage the pipettor The single use of the tip reduces the risk of contamination of samples Keep the pipettor clean avoiding the use of aggressive substances e g acetone for cl...

Page 5: ...ower position A B C The accuracy and precision are obtained gravimetrically using Corning pipet tips performing at least 10 measurements of distilled water at a temperature of 20 C 1 C according to th...

Page 6: ...unter operating mode switch the calibration switch located under the CAL sign on the counter overlay This switch should only be used when the pipettor is calibrated upper position marked as CAL on the...

Page 7: ...film remains relatively constant in successive pipetting operations with the same tip this error can be eliminated by forming the film before transferring the first sample This is done by aspirating a...

Page 8: ...holding the handle unscrew the remaining part of the shaft holder set from it Then proceed according to the pipettor models shown below See ISO 8655 for the full table of the value of the conversion f...

Page 9: ...d in the case of pipettor 2 L also the Seal P If you need to clean other components Unscrew the Shaft Cap M Remove from the Plunger I and pipetting Spring N Remove the Shaft J from the Connecting Bush...

Page 10: ...g Spring N from the shaft Remove the Shaft J from the Connecting Bush L If necessary remove the Seal P from the Plunger I Check the condition of components and clean as recommended Replace any damaged...

Page 11: ...ny damaged parts Assemble the components in reverse order When inserting the shaft or the shaft holder set into the Connecting Bush make sure that they are inserted all the way to the end by gently ro...

Page 12: ...ealing elements e g after repeated autoclaving procedures Sterilization Sterilization in an autoclave The pipettor can be sterilized in an autoclave at 121 C for 20 minutes Sterilization under other c...

Page 13: ...Shaft Kit with seal and O ring 2 SP9811 1 J O Shaft kit with O ring 10 SP9812 1 20 SP9813 1 J Shaft 50 100 SP9814 1 200 SP9815 1 1000 SP9816 1 L Connecting Bush All SP9810 1 H Tip ejector 2 10 SP9817...