background image

 

 

 

 

 

 

High Power Remote Unit 2.3/2.5GHz Tune up procedure

   

 

 

   
   
 

Index 

 

 

1 INTRODUCTION

.................................................................................................................................... 2 

2 PREPARATION

 ...................................................................................................................................... 2 

2.1. PERSONAL PREPARATION

 ........................................................................................................ 2 

2.2 POSITION AND CONNECTION

 ................................................................................................... 3 

2.3 POWER UP AND INDICATORS

 ................................................................................................... 4 

3.      OMT OPERATION

 ........................................................................................................................... 6 

3.1 SET IP ADDRESS OF COMPUTER

 ............................................................................................... 6 

3.2 CONNECT DEVICE VIA OMT

 ...................................................................................................... 6 

3.3 EQUIPMENT PARAMETERS

 ....................................................................................................... 7 

 
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   

Summary of Contents for GX-WCSM2500M-40

Page 1: ... procedure Index 1 INTRODUCTION 2 2 PREPARATION 2 2 1 PERSONAL PREPARATION 2 2 2 POSITION AND CONNECTION 3 2 3 POWER UP AND INDICATORS 4 3 OMT OPERATION 6 3 1 SET IP ADDRESS OF COMPUTER 6 3 2 CONNECT DEVICE VIA OMT 6 3 3 EQUIPMENT PARAMETERS 7 ...

Page 2: ... Operating person should be with necessary knowledge of electronic RF and familiar with local regulation rules b Personnel shall read through the manual instructions guide carefully before operation c Check if there is warning alert sign on the equipment to avoid possible danger d Wear proper cloth If necessary equip with PPE Personal Protective Equipment e Before operation procedures and data rec...

Page 3: ...he antistatic bag from repeater enough caution shall be taken to avoid ESD The Anti static Wrist Strap is recommended 2 2 POSITION AND CONNECTION 1 Equipment experimental position Equipment shall be placed in stable position during testing e g place on a table or stand on the floor Be aware of the table shall be firm enough to support the equipment 2 Connections WCS TDD 2 5 MIMO WCS TDD 2 5 SISO O...

Page 4: ...an cable to computer can be connected before or after power up 2 3 POWER UP AND INDICATORS Before power up please check product voltage requirement and make sure the equipment is with good grounding protection Warning Always be caution to voltage safety Before hands on operation check if the equipment is powered off and disconnected from power supply or otherwise will cause personnel injury and eq...

Page 5: ...cates the status of a particular function Identifier Color Indication RUN Green On The system is not ready system need 2 3min after power up to be ready Blink The system is boot up and normal Off The system is no power supply or MCU is not working ALM Red Off No Alarm occurring On Alarm occurring FSK Green Off No communication between OCH Equipment Blink Communication normal between OCH Equipment ...

Page 6: ...te It s strongly recommended to keep the equipment IP address in default value 3 2 CONNECT DEVICE VIA OMT Double click CMA OMT Software V5 00 on the desktop after OMT installation Choose Connection via Ethernet Note this is a special version of OMT A general version of OMT is not applicable Click Connect F5 in the up left corner and click connect in the pop up window keep every parameter in its de...

Page 7: ... RF parameter check equipment property parameters are correctly set Equipment Property parameters Serial No Identifier of the equipment Every piece of equipment has a unique ID Correct S N ensures the communication between OCH and CRU Site ID Site Sub ID This is the indicator for Site information ...

Page 8: ...switches are off of new equipment from the factory Particular switch has to be turned on for real application or RF testing Service On Off ATE service 1 4 Manufacturer level control This switch has the highest priority Turn on for expected service first Service On Off service 1 4 User level control This switch has the second highest priority Turn on for expected service ...

Page 9: ... the compensation of fiber optical loss Strongly recommend to turn this switch on for normal application Equipment Power DL Output Max Power service 1 4 This parameter sets the maximum output level of each service The range is from 16dBm 47dBm DL Output Power service 1 4 This is the read only value of the DL power of each service FSK Rx Power Threshold Default is 65dBm this value can be set smalle...

Page 10: ...etting different DCA attenuators It is recommended to set DL UL Manual DCA to change to attenuators to control the output power After setting the DL UL Manual DCA DL UL operational DCA will be refreshed to the same value as DL UL Manual DCA ...