2.4
Additional stack and DRU connections
¾
For connections to additional IHU or HEU and DRU units:
Using the appropriate length ERFC cable (according to distance of available OIX/RIX port) connect remaining
IHU RIX and OIX module connectors as follows:
•
Connections to additional IHU unit:
IHU #1 RIX 9-Pin connector to the corresponding IHU #2 OIX module
IHU #1 OIX 9-Pin connector to the corresponding IHU #2 RIX module
•
Connections to additional HEU and OIU units:
IHU RIX 9-Pin connector to the corresponding connector on the OIX module of the additional OIU.
IHU OIX 9-Pin connector to the corresponding connector on the RIX module of the additional HEU.
Note: The RIX and OIX modules of the additional HEU unit must also be connected.
See use cases for details, section 1.4.1