![CORNING CCH 1U Quick Start Manual Download Page 3](http://html1.mh-extra.com/html/corning/cch-1u/cch-1u_quick-start-manual_2668654003.webp)
STANDARD RECOMMENDED PROCEDURE 003-876-QSG | ISSUE 2 |
OctOber
2011 | PAGE 3 OF 6
4.2. sheath retention
4.3.
Strain-relieving to the Transitional Strain-Relief Holder
TPA-3877
Bundle of small
diameter cable:
Cable tie bundle together,
then cable tie to all 4 bridges
Small diameter cable:
Cable tie to 2 bridges
Large diameter cable:
Cable tie to all 4 bridges
TPA-3883
4.3a
4.3a
4.3a
Replace blank panels with adapter
panels applicable for the
connectors being used.
4.3b
Press buffer tube
fan-out bodies into
transitional holder.
OR Secure loose tube
cable to the transitional
holder with cable ties.
4.3c
In 2U or 3U housings,
you may stack the
transitional holder to
accommodate more
fan-out bodies or cables.