
16
SGHN4-300E Series
380V/400V/415V
REVISION # 0000
DATE: 12/26/2019
D. LCD Display Instruction:
Display
Status
Display
Status
T1
T1 setting
T1 or T2 or T3
setting completed
T2
T2 setting
Door closing
T3
T3 setting
Door opening
E. Light Indication:
5
4
3
8
9
18
16
17
LED16 STOP Control station stop
ON: Connect with 3 button
control station and not
activate STOP button.
OFF: Not connect with 3
button control station
or activate STOP
button.
LED3 OLS Door open limit
ON: Door at open limit.
OFF: Not at open limit.
LED5 CLS Door close limit
ON: Door at close limit.
OFF: Not at close limit.
LED4 SLS AUX close Limit contact
ON: Door at AUX close limit.
OFF: Not at AUX close limit.
LED17 OPEN Open button
ON: Activated.
OFF: Not activated.
LED18 CLOSE Close button
ON: Activated.
OFF: Not activated.
C.
L.S
.
LED30
VVS
SAFE
CLOSE
S.
L.
S.
STOP
OPEN
DEVICE
O.
L.S
.
L
ED9 SAFE Sensing device
ON: Sensing device circuit activated.
OFF: Sensing device circuit ok or not
activated.
LED8 DEVICE Device light
ON: When the sensing device connected
on terminal CN2 (E5,E6/P5,P6) is
normal.
OFF: Sensing device disconnected, failed
or damaged.
Summary of Contents for SGHN4-300 E Series
Page 18: ...17 SGHN4 300E Series 380V 400V 415V REVISION 0000 DATE 12 26 2019 ...
Page 19: ...18 SGHN4 300E Series 380V 400V 415V REVISION 0000 DATE 12 26 2019 ...
Page 20: ...19 SGHN4 300E Series 380V 400V 415V REVISION 0000 DATE 12 26 2019 ...
Page 21: ...20 SGHN4 300E Series 380V 400V 415V REVISION 0000 DATE 12 26 2019 ...