9
FS-150EP Series
230V, 50Hz
REVISION # 0000
DATE: 02/18/2021
Disconnect power at the fuse box before proceeding with any wiring.
2. Locate the control station where the user can
clearly see the operation of the door. Mount
the enclosed placard adjacent or near the
door.
Controls shall be far enough from the door, or positioned such that the
user is prevented from coming in contact with door while operating the
controls.
3. Do not run control wiring in the same conduit as power wiring.
4. Any wire connected to the control panel must be protected by conduit or other means to ensure the
safety and permanency of the wiring.
Do not use radio controls with your operator unless some type of
entrapment protection device has been installed. Failure to do so may
result in death or serious injury to person(s) trapped beneath the door.
Changing from left hand to right hand or vice versa could result in change
of control wiring. Consult factory for details.
5. After installation, be sure that the operator, controls, and sensing edge or other entrapment
protection devices have been tested and function properly.
WARNING
WARNING
WARNING
WARNING