Viper Service Manual
Publication Number: 621260373SER
- 54 -
© 2008-2016, Cornelius Inc.
Figure 43. Side View of Motor Showing Two of the Four Mounting Bolts
M
OTOR
R
UN
C
APACITOR
R
EPLACEMENT
The motor run capacitors, shown in Figure 44, are mounted at the rear of the unit between the barrel motors. To
replace a run capacitor, perform the procedure in Table 47.
Figure 44. View of Motor Run Capacitors
Table 46.
Step
Action
1
Perform the procedure in Steps 1 through 8 of Table 43.
2
Disconnect the motor from the circuit by unplugging the connector.
3
Remove the motor by removing the four (4) bolts holding the motor to the bar-
rel assembly.
4
Install the replacement motor and connect the connector.
5
Replace the motor seal, scraper blade assembly onto the motor shaft in the
barrel, as described in Table 43.
6
Reconnect power to the unit.
7
Refill the barrel with product. See “Filling a Barrel” on page 32.
8
When barrel fill is complete, perform a motor calibration. See “Calibrating a
Motor” on page 38.
Barrel Motor
Mounting
Bolts
Foam
Pack
Motor Run
Capacitor
Motor Run
Capacitor