Viper Service Manual
© 2008-2016, Cornelius Inc.
- 23 -
Publication Number: 621260373SER
Error Log Menu
The Error Log screen displays information about any errors generated by the unit, as shown in Figure 17. If no
errors have been detected, the right side of the display is blank. To view more than one error, press the Up or Down
arrows on the right side of the display to scroll through the error log. Button functions are described in Table 8.
ERROR
LOG
12:51P
MAR 04
ERROR NUMBER 2
#3 COMM FAIL
BACK
OCCUR: 2:44 PM
3/04/08
CLEAR: 2:52 PM
3/04/08
Figure 17. Error Log Screen
COM ERR
STAT
Limp
Communications error, the system continues to run.
HIGH VOLT-
AGE
System
The unit is experiencing voltage greater than 260VAC. System is enabled
when line voltage drops below 260VAC for two minutes.
LOW VOLT-
AGE
System
The unit is experiencing voltage less than 200VAC. System is enabled when
line voltage rises above 200VAC for two minutes.
NO MOTOR
Barrel
The motor is reporting no current draw when activated. Motor is unplugged
or thermal cutoff has tripped.
FILL ERROR
Barrel
Barrel has not filled properly within 2 min.
H
2
O OUT
System
Water pressure is too low for proper operation. This error occurs when the
H
2
O sensor reports no or low water pressure for more than one second.
Error is cleared 10 sec. after restoral.
CO
2
OUT
System
CO
2
pressure is below required operating pressure. This error occurs when
the CO
2
sensor reports no or low CO
2
pressure for more than one second.
Error is cleared 10 sec. after restoral.
SYRUP OUT
Barrel
Syrup pressure is below required operating pressure. This error occurs when
the syrup sensor reports no or low syrup pressure for more than one second.
Error is cleared 10 sec. after restoral.
CLOCK
System
The real time system clock is not functioning.
MTR CTL
EEPROM
System
Motor control EEPROM is bad or missing.
Table 7.
Button
Description
BACK
Returns the display to the Select menu
RESET
Allows the user to reset the highlighted error (This button only
appears on certain manually resettable errors.)
Button
Description
BACK
Returns the display to the Select menu
Table 6.
Displayed
Message
Action
Type
Description