background image

Viper 3 Flavor Plumbing Installation Instructions

Publication Number: 629096928INS

- 2 -

© 2008-2017, Cornelius Inc.

I

NSTRUCTIONS

V

IPER

 3 F

LAVOR

 P

LUMBING

The following instructions should be used for installation of the CO

2

, Water and Syrup plumbing for a Viper 3 Fla-

vor FCB unit at a maximum distance of 50 feet from the unit. Prior knowledge of the FCB Installation/Service 
Manual is necessary before attempting the installation.

C

ART

 I

NFORMATION

 

AND

 M

OUNTING

The Viper unit may be mounted on a mobile cart (Cornelius part no. 620043075 for 2-barrel unit, 620053990 for 
3-barrel unit and 620046556 for 4-barrel unit) which allows some movement of the unit for service and cleaning. 
There are four captive nuts on the bottom of the Viper to accommodate four 3/8-16 bolts. These bolts must be 
installed to secure the unit to the cart.

These carts are also designed with movable wheels that act as outriggers to provide stability to the unit when it is 
being moved.

!

WARNING:

The above listed mounting bolts must be installed and the wheels extended and locked in the outboard position 
prior to moving the unit. 

Failure to comply could result in serious injury, death or equipment damage.

Parts List:

Table 1. Parts List

Sl. No.

Part No.

Description

Quantity

UOM

1

08859

Tie Cable, 11” Std. Dennison

10

EA

2

174478000

Tubing Flexcor 265 X 465 500’/Ctn.

8

FT

3

178025100

Gasket, 1/4 Male Flare Fitting

5

EA

4

309852000

Clamp OETR 669 Open Stpls #17.0

10

EA

5

312926000

Clamp OETR 484 Open Stpls #12.3

24

EA

6

77062000

Fitg C-Brb 3/8 (4)

1

EA

7

113375000

Tubing, Vinyl .375 X .625 Transparent

18

FT

8

50418

Bag, Plastic

1

EA

9

620807202

Bag, Plastic 10 X 13 Ziplock, 2 mil

1

EA

10

629096928INS

Manual Installation Kit, 3 Flavor 
Plumbing

1

EA

11

77010100

Nut, Swivel 7/16-20 BRNI

1

EA

12

77010400

Fitting, NIPL 265 Tube 1/4FL Nut SS

1

EA

13

77060200

Fitting, C-Barb 1/4 (4) SS

1

EA

14

48114008

Clamp 779open Stpls #19.8

5

EA

15

620058256

Tubg Uv Resist 510x740 

50

FT

16

620717792

Tubg Sg 375id X 535 Taste Rite 
Braided 

250

FT

17

630900020

S-crtn Wrap I Series Evap

1

EA

18

77046500

Fitg Swiv  7/16-20f 3/8brb

5

EA

19

77060100

Fitg T-brb 1/4 (3) Ss 

4

EA

20

111353000

Clamp 571 Open Stpls #14.5

30

EA

21

620066599

Reg Flow Water 50 Psi Fixed

1

EA

22

77040700

Splicer Barb 250 X 375 Stn Stl

3

EA

Summary of Contents for VIPER 3 FLAVOR

Page 1: ...it All wiring and plumbing must conform to national and local codes Failure to comply could result in serious injury death or equipment damage SAFETY PRECAUTIONS This unit has been specifically designed to provide protection against personal injury To ensure continued protection observe the following WARNING Disconnect power to the unit before servicing Follow all lock out tag out procedures estab...

Page 2: ...els extended and locked in the outboard position prior to moving the unit Failure to comply could result in serious injury death or equipment damage Parts List Table 1 Parts List Sl No Part No Description Quantity UOM 1 08859 Tie Cable 11 Std Dennison 10 EA 2 174478000 Tubing Flexcor 265 X 465 500 Ctn 8 FT 3 178025100 Gasket 1 4 Male Flare Fitting 5 EA 4 309852000 Clamp OETR 669 Open Stpls 17 0 10...

Page 3: ...o consid eration the total potential water demand that may be placed on the store water supply by all equipment within the store Equipment such as fountain dispensers icemakers coffee brewers and juice dispensers typically draw water from a common source filter system The FCB machine must be supplied with water to the specification above at all times even when any of the other equipment is drawing...

Page 4: ...erage T ubing Inch Beverage T ubing 3 8 Inch T ygon T ubing A B C D E Outlet on Syrup Pump 2 5HJXODWRU 6HFRQGDU Inch Female Flare Nut Direct Connection to Syrup Outlet on Syrup Pump Direct Connection to CO2 Inlet on Syrup Pump Direct Connection to Syrup Direct Connection to Syrup Inlet on Syrup Pump Water Inlet Syrup Line 1 CO2 Inlet BIBSyrup BIBSyrup BIBPump C E D G BIBPump C E D Syrup Line 2 Syr...

Page 5: ...res a dedicated 3 8 CO2 line with a regulator located at the unit An additional dedicated 3 8 CO2 line is required with a regulator located at the BIB rack Viper 3 Flavor Plumbing Installation Instructions 2008 2017 Cornelius Inc 5 Publication Number 629096928INS Viper CO2 setup Single unit Figure 2 Viper CO2 setup single unit ...

Page 6: ...g in Box 3 8 Lines 75 1 psig 75 1 psig NOTE Each unit requires a dedicated 3 8 CO 2 line with a regulator located at the unit An additional dedicated 3 8 CO 2 line is required with a regulator located at the BIB rack Viper 3 Flavor Plumbing Installation Instructions Publication Number 629096928INS 6 2008 2017 Cornelius Inc Viper CO2 setup Multiple unit Figure 3 Viper CO2 setup multiple unit ...

Reviews: