Continuous Flow Icemaker Service Manual                              

Publication Number: 630460174SER

- 6 -

© 2004-2011, IMI Cornelius Inc.

B

IN

 C

ONTROL

The type of bin control used on all WCC & WCF Models 
is an electronic control. The control is supplied with 
power to terminals X1 and X2. Terminals X3 and X4 are 
a normally closed switch which open when the 
thermostat sensor bulb senses ice.

The sensing element is located in a 5/16” stainless steel 
tube which hangs from the dispense tray cover down 
through the center of the drop tube.

To test switch, start the icemaker and block the outlet 
tube. When the ice fills the drop tube about 1/2 full the 
icemaker should shut off. When tube is cleared the ice 
maker should restart within 5 min.

The Bin control is in electrical series with coil on antifreeze relay along with the low water safety. If unit is water 
cooled, the condenser high pressure cut out is also in series.

The Control Switch is held in place inside electrical box by 2 screws. The Control bulb is in the drop tube. It can 
be removed by pulling the cable located on the top of the dispense tray cover. When replacing the sensor make 
sure the bulb is inserted to the bottom of the thermostat well.

G

EARMOTOR

The gearmotor is equipped with a start relay and a manual reset overload.

When current is applied, the relay energizes and completes the circuit to the start winding. The motor reaches a 
predetermined speed and the relay drops out, disconnecting the start winding. The run winding remains in the 
circuit as long as current is applied.

The purpose of the overload is to automatically shut off the motor in the event of a mechanical bind of the 
transmission, an overload condition within the evaporator or an electrical malfunction. It does this by sensing 
amperage draw. If the motor stalls the start relay would energize and stay energized. The amperage would surge 5 
to 6 times greater than the normal draw. In this event the overload would shut off the transmission in 4 to 8 
seconds.

If the motor is subjected to an abnormal load, but does not reach a stall condition, the overload will react, but over 
a greater period of time. The reaction time depends upon the amperage to which it is subjected.

The overload, through the safety circuit, also shuts off the compressor.

Figure 4. Bin Control Switch

BIN CONTROL 
SWITCH TERMINALS

Summary of Contents for Quantum 1000

Page 1: ...500 700 1000 2000 Series Service Manual Release Date May 27 2004 Publication Number 630460174SER Revision Date February 24 2011 Revision E Visit the IMI Cornelius web site at www cornelius com for al...

Page 2: ...rvice required by or loss or damage resulting from any of the following occurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Pr...

Page 3: ...ontrol Works 9 Purpose 9 To Replace Water Level Control 9 To Replace Water Level Safety Switch 9 Electrical 10 Refrigeration System 13 Refrigeration System Adjustments 13 Expansion Valve 13 Adjustment...

Page 4: ...r moderate injury or equipment damage SAFETY TIPS Carefullyreadandfollowall safety messages inthismanualandsafety signsontheunit Keepsafety signsin goodconditionandreplace missingordamageditems Learnh...

Page 5: ...off to the unit before any work is performed Failure to disconnect the power could result in serious injury death or equipment damage CAUTION Always be sure to keep area around the unit clean and fre...

Page 6: ...115 60 1 2 12 N A 2 13 R404A 20 WCC711 A Air Cooled 208 230 60 1 2 7 7 1 6 2 24 R404A 20 WCC711 W Water Cooled 208 230 60 1 2 7 7 N A 2 13 R404A 20 WCF712 A Air Cooled 220 240 50 1 2 8 2 0 5 1 6 24 R4...

Page 7: ...500 700 DIMENSION DRAWING SHIPPING WT 160 LBS APPROX Figure 2 Series 1000 Dimension Drawing Shipping Wt 210 Lbs Approx 22 00 27 00 FRONT 24 00 SIDE BACK VIEW AIR COOLED ELECTRICAL 7 8 DIA WATER UB 1...

Page 8: ...2 25 23 50 18 13 WATER IN ELECTRICAL 7 8 DIA DRAIN 3 8 I D TUBE 9 50 20 13 3 81 ICE DISCHARGE 2 06 BOTTOM FRONT 2 06 Continuous Flow Icemaker Service Manual 2004 2011 IMI Cornelius Inc 5 Publication...

Page 9: ...f the dispense tray cover When replacing the sensor make sure the bulb is inserted to the bottom of the thermostat well GEARMOTOR The gearmotor is equipped with a start relay and a manual reset overlo...

Page 10: ...Turn off machine and remove all ice 9 Sanitize using household liquid bleach 50 ppm chlorine Mixture 1 fluid ounce per gallon room temperature water 2 minute exposure time 10 Sanitize auger diverter...

Page 11: ...ittings and lower icemaker water seal 2 Check drain tubes for clogs and aged tubes Replace if tubes are stained or brittle 3 Check for signs of condensation Clean where necessary and replace insulatio...

Page 12: ...provides a visible check of water level but also is a good guide to the internal conditions which exist within the icemaker assembly itself See Cleaning Procedure TO REPLACE WATER LEVEL CONTROL WARNIN...

Page 13: ...Continuous Flow Icemaker Service Manual Publication Number 630460174SER 10 2004 2011 IMI Cornelius Inc ELECTRICAL Figure 6 Schematic And Wiring Diagram WCC2001 A AND WCF2201 A...

Page 14: ...ER Figure 7 schematic and wiring diagram wcc500 a wcc500 w wcc700 a wcc700 w wcf510 a wcf510 w wcf710 a wcf710 w Figure 8 Schematic And Wiring Diagram WCC701 A WCC701 W WCC1001 A WCC1001 W WCF711 A WC...

Page 15: ...Service Manual Publication Number 630460174SER 12 2004 2011 IMI Cornelius Inc Figure 10 Schematic And Wiring Diagram WCC502 WCC702 WCC1002 WCF512 WCF712 WCF1102 Figure 11 Schematic And Wiring Diagram...

Page 16: ...properly Second take reservoir water temperature and air temperature from condenser inlet and determine at what pressure unit should be running Machines are equipped with thermostatic valves there is...

Page 17: ...low with the refrigeration system high side pressure turn adjustment screw located on end of valve opposite of bellows Turn screw counterclockwise to raise opening point or clockwise to lower opening...

Page 18: ...ms OVERLOAD GUIDE ELECTRICAL High or low voltage Weak power lines can cause overloads on icemakers restarts High running current 2 4amps or above Check motor circuits and start relay Auger delay faile...

Page 19: ...ings must be used The start relay cover must be removed If no continuity on start or run winding test replace gearmotor If continuity on grounded motor test replace gearmotor START RELAY WARNING Disco...

Page 20: ...rth to align the motor shaft and auger Figure 15 Auger and Extruding Head Removal INSTALLATION AND SHAFT SEAL REPLACEMENT 500 1 Place shaft seal locator seat over gear motor output shaft embossed side...

Page 21: ...e performing any work Failure to comply could result in serious injury death or damage to the equipment WARNING 1 Disconnect unit from power supply 2 Remove storage container cover and put aside 3 Tur...

Page 22: ...rn counterclockwise to remove assembly 5 Remove worn bearings Replace with new bearings and then reinstall assembly NOTE If auger turns with nut remove cover on top of gearmotor stator and hold motor...

Page 23: ...to the equipment Using a volt ohmmeter check the continuity across the overload contact 1 and 3 If none wait for unit to cool down and try again If still no continuity the overload protector is defec...

Page 24: ...tion Failure to comply could result in serious injury death or damage to the equipment The safety and control system shut off devices are 1 Low water shut off reed switch located in icemaker float ass...

Page 25: ...262 ppm sodium chlo ride Normal water supply too high in total dissolved solids above 500 PPM It runs but the ice is too soft The icemaker is not producing enough ice The ice is too wet Check for loo...

Page 26: ...uction line not insulated Bulb uninsulated Clean and insulate TXV not operating properly Bulb loose Clean and tighten Head Pressure high Valve stuck open Replace valve Condenser dirty or restricted Co...

Page 27: ......

Page 28: ...IMI Cornelius Inc www cornelius com...

Reviews: