TROUBLESHOOTING GUIDE
13
Problem
Probable Cause
Remedy
FROM SINGLE VALVE,
UNIT IS DISPENSING
WATER ONLY
Concentrate container empty.
BIB connector is not engaged
or improperly installed.
Air leak in product suction
line.
No power at the pump motor.
Defective gear motor
assembly.
Pump running backwards.
Defective concentrate pump
tubing.
Replace.
Check BIB connector for proper
installation. Plunger should be
completely inserted with concentrate
filling the line to the dispenser.
Check the 3/8 flare connection where
the product line attaches to the unit.
Tighten fitting using a flare gasket. If
line is drawing air, pump will not
prime.
Check for broken or loose wire
connection going to pump motor.
Check for 26 VDC at pump motor
when the dispense button is
energized.
Check motor function by energizing
circuit with the dispense button. If
motor runs, but pump does not turn,
a broken gear box is indicated. The
pump motor and gear box are
replaced as a unit.
Check the direction of pump
rotation...correct rotation is clockwise
as viewed from the front of the unit.
If pump is turning in a counter
clockwise direction, this indicates the
pump wires are reversed.
Check the pump tubing for ruptures ,
wear, etc. Replace as needed
following the instructions printed in
this
manual.
DISPENSER IS BRIXING
OUT
TOO HIGH
Supply water pressure too low.
Defective flow control.
Low viscosity or highly
Water pressure must be 20 psi
flowing or above.
Disassemble and check flow control
assembly for binding, defective
compensating spring , trapped debris.
Be sure the spool moves freely within
the sleeve, replace parts as needed.
Locate the pump switches grouped
Summary of Contents for MILLENNIUM MJ40-6PB
Page 8: ...7 NOTES...
Page 19: ...MILLENNIUM 6 VALVE WIRING DIAGRAM 18...
Page 28: ...VALVE BLOCK ASSEMBLY P N 45045 27...
Page 30: ...PORTION CONTROL ASSEMBLY 29...
Page 31: ...PORTION CONTROL ELECTRICAL DIAGRAM P N 48443 001 30...