Cornelius IDC 2XX Operator'S Manual Download Page 8

IDC Operator’s Manual

© 2005-2010, IMI Cornelius Inc.

- 5 -

Publication Number: 621057403OPR

Monthly Cleaning: (In addition to daily and weekly procedures)

1.

Flush and sanitize all syrup lines as well as all of the syrup connectors. (See the sanitize syrup lines 

section shown later in this manual). 

2.

Remove ice from hopper and clean and sanitize the hopper. (See the Cleaning the interior surfaces 

section shown later in this manual).

3.

While cleaning the hopper use the brush provided with the unit to clean the cold plate surface. To 

accomplish this, the brush needs to be extended through the opening in the bottom of the hopper. 

Yearly Maintenance:

•    Have the water pump and check valve inspected and cleaned by a qualified service technician. 

•    Have the CO2 gas check valve inspected and cleaned by a qualified service technician.

•    Remove the unit’s splash and cold plate cover to clean and sanitize the cold plate surface. (See the 

     cleaning the cold plate section shown later in this manual ).

Cleaning Interior Surfaces (Monthly Cleaning)

CAUTION:

!

       When pouring liquid into the hopper, do not exceed the rate of 1/2 gallon per minute. Pouring more liquid into the
       hopper could result in an overflow situation may result in injury or damage to the equipment.

1. Remove agitator assembly.
2. Using a nylon bristle brush or sponge, clean the interior of the hopper, top cover and agitator assembly 

with  soap solution. Thoroughly rinse the hopper, cover and agitator surfaces with clean potable water.

3. Reassemble agitator assembly. Take special care to ensure that the thumbscrew is tight.
4. Using a mechanical spray bottle filled with sanitizing solution, spray the entire interior and agitator 

assembly. Allow to air dry.

5. Remove merchandiser and ice chute cover from unit.
6. With a nylon bristle brush or sponge, clean the inside of the ice chute, gasket, and cover with soap solu-

tion and rinse thoroughly to remove all traces of detergent.

7. Reassemble ice chute assembly.
8. Using a mechanical spray bottle filled with sanitizing solution, spray the inside of the ice chute. Allow to 

air dry.

9. Reinstall merchandiser.

Cold Plate (Yearly Maintenance)

1. Remove splash panel.
2. Remove or move the plastic cold plate cover to expose the cold plate.
3. Locate and remove any debris from the drain trough. Check that the drain holes are not clogged.
4. Pour small amount of soap solution through cold plate openings in hopper.
5. Using a cloth, wash down the surfaces of the cold plate and plastic cover with soap solution. 
6. Install and properly position the access covers on the cold plate.
7. Install the splash panel in the reverse order it was removed.
8. Rinse cold plate surface by pouring potable water through hopper openings.

Summary of Contents for IDC 2XX

Page 1: ...d Carbonation Operator s Manual Release Date October 18 2005 Publication Number 621057403OPR Revision Date August 3 2010 Revision F Visit the IMI Cornelius web site at www cornelius com for all your L...

Page 2: ...rvice required by or loss or damage resulting from any of the following occurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Pr...

Page 3: ...r on a Counter 2 Start up and Operating Instructions 3 Ice Drink Dispenser 3 Cleaning and Maintenance Instructions 4 Daily Cleaning 4 Daily Maintenance 4 Weekly Cleaning 4 Monthly Cleaning 5 Yearly Ma...

Page 4: ...damage SAFETY TIPS Carefully read and follow all safety messages in this manual and safety signs on the unit Keep safety signs in good condition and replace missing or damaged items Learn how to oper...

Page 5: ...residual sanitizing solution or water remaining inside the unit to freeze resulting in damage to internal components CO2 CARBON DIOXIDE WARNING DANGER CO2 displaces oxygen Strict attention MUST be ob...

Page 6: ...chunks of ice which jam up inside the hopper will cause failure if the agitator motor and damage to the hopper If bagged ice is used it must be carefully and completely broken into small cube sized p...

Page 7: ...water and allow to air dry 2 Wipe down the exterior of the unit with warm soapy water rinse with clean water and allow to air dry 3 Remove valve nozzles and diffusers and wash in warm soapy water rins...

Page 8: ...ve agitator assembly 2 Using a nylon bristle brush or sponge clean the interior of the hopper top cover and agitator assembly with soap solution Thoroughly rinse the hopper cover and agitator surfaces...

Page 9: ...rent product tube each time until all tubes are filled with the sani tizing solution 11 Remove the nozzle and syrup diffuser and clean them in a mild soap solution Rinse with clean water and reassembl...

Page 10: ...o avoid personnel injury and or property damage always secure the CO2 cylinder with a safety chain to prevent it from falling over Should the valve become accidently damaged or broken off a CO2 regula...

Page 11: ......

Page 12: ...IMI Cornelius Inc www cornelius com...