Cornelius ID-90 Series Installation And Service Manual Download Page 7

 Landmark Ice Dispenser Installation and Service Manual

© 2004-2014, Cornelius Inc.

- 3 -

Publication Number: 60418002

I

CE

 G

ATE

 A

DJUSTMENT

An ice gate is provided to control the dispensed flow rate of ice. The ice gate is mounted on the 
positioning tab at the end of the static bar. The ice gate may be adjusted for the type and size of ice being 
used. Once set no further adjustments should be necessary.

Prior to adjusting the ice gate position, be sure to 

disconnect power to the dispenser 

to prevent the 

agitator from rotating while adjusting the ice gate.

Fill bin with ice up to the chute to a depth of approximately 6 inches from the bottom of the bin. With a cup 
held below the ice chute, press the ice dispense button or lever. If the flow rate needs adjustment, 
disconnect power and remove static bar assembly (see Figure 2). Reposition ice gate to either the 

fast, 

medium, 

or 

slow 

position as shown in Figure 1. Carefully reinstall static bar assembly as described in 

Figure 1.

C

LEANING

 

AND

 M

AINTENANCE

The dispenser must be cleaned and sanitized after installation and, thereafter, as required by state 
and local health departments, or every three months minimum.

Continuous maintenance of this unit is a basic requirement for proper operation and sanitation, including 
all support equipment utilized in the daily operation of this equipment.

FIGURE 2

Summary of Contents for ID-90 Series

Page 1: ...ISPENSERS Installation and Service Manual Release Date June 15 2004 Publication Number 60418002 Revision Date March 21 2014 Revision F Visit the Cornelius web site at www cornelius com for all your Li...

Page 2: ...ccurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Product 2 improper volt age 3 inadequate wiring 4 abuse 5 accident 6 altera...

Page 3: ...Publication Number 60418002 TABLE OF CONTENTS General Description 1 Unpacking and Inspection 1 Location Requirements 1 Installing Unit 1 Ice Gate Adjustment 3 Cleaning and Maintenance 3 Cleaning Equi...

Page 4: ...Landmark Ice Dispenser Installation and Service Manual Publication Number 60418002 ii 2004 2014 Cornelius Inc...

Page 5: ...claim with the delivering carrier After removal of shipping carton remove parts from the ice compartment LOCATION REQUIREMENTS Use a separate 120VAC 60HZ 1PH 15 AMP grounded duplex outlet to accommod...

Page 6: ...ecked for leaks and sanitized the unit is now ready for operation NOTE Static Breaker bar in the ice bin MUST BE situated inside the right of the dispense door as you face the front of the unit or no...

Page 7: ...to the chute to a depth of approximately 6 inches from the bottom of the bin With a cup held below the ice chute press the ice dispense button or lever If the flow rate needs adjustment disconnect po...

Page 8: ...Bucket Small Brush CLEANING AND SANITIZING PROCEDURE The ice bin should be thoroughly cleaned and sanitized at least once every month or as required by state and local health departments WARNING When...

Page 9: ...solenoid Dispenser will not dispense ice No Power Check electrical connections Solenoid Malfunction Replace solenoid Dispenser overloaded with ice Remove ice from dispenser until unit will operate Mot...

Page 10: ...CAUSE SOLUTION Dispensing Crushed Ice or Reduced Dispensing Speed Water spillage from field installed ice making machine Adjust ice maker Bridge of ice sheet is too thick Adjust field installed ice m...

Page 11: ...Landmark Ice Dispenser Installation and Service Manual 2004 2014 Cornelius Inc 7 Publication Number 60418002 FIGURE 4 Wiring Diagram Timed Agitation...

Page 12: ...Landmark Ice Dispenser Installation and Service Manual Publication Number 60418002 8 2004 2014 Cornelius Inc...

Page 13: ......

Page 14: ...Cornelius Inc www cornelius com...

Reviews: