© 2012, IMI Cornelius Inc.
Figure 14.
Figure 15.
5
Peel back the insulation on the pump tubing, shown in Figure 16.
6
Remove the inlet and outlet plumbing from the pump, as shown in Figure 17.
7
Carefully cut the tape holding the two halves of the insulation together
around the recirculating pump. (See Figure 17.) Save the insulation.
8
Loosen the retaining collar, shown in Figure 18.
9
Remove the recirculating pump assembly by pulling it away from the motor.
10
Install the new recirculating pump assembly onto the motor and tighten the
pump retaining collar.
11
Reinstall the insulation around the pump and over the pump tubing.
12
Check and replace the gasket inside the fittings, shown in Figure 14, before
reconnecting the pump.
13
Reconnect the inlet and outlet plumbing to the pump, using teflon tape to
insure a proper seal.
14
Turn the water supply on and make sure the water bath level is up to the
notch in the overflow tube.
15
Open the appropriate recirculating shutoff valves, shown in Figure 15.
16
Turn on the CO
2
supply to the unit and check the system for leaks.
17
Turn on the electrical supply to the unit.
18
Turn on the water supply to the unit.
19
When the unit is refilled, replace the unit cover.
Table 14.
Step
Action
Circuit 1
Valves
Circuit 2
Shutoff
Shut off
Valves
Summary of Contents for Energize6