Energize6 Service Manual
© 2012, IMI Cornelius Inc.
- 15 -
Publication Number: 621058457SER
Figure 11.
C
LEANING
AND
S
ANITIZING
THE
S
YRUP
S
YSTEM
To effectively clean and sanitize the syrup lines, a two-step process must be used.
This two-step process includes: Cleaning the system with a cleaner solution, and
rinsing it with water, then sanitizing the system with sanitizer.
Materials required:
• 15 gallons of sanitizing solution (Kay-5 or equivalent - 200 ppm)
• One gallon of mild detergent solution
• Sanitizing fittings or B-I-B end fittings
• One 1-gallon pail (minimum)
• One 5-gallon pail (minimum)
• One nylon brush
Cleaning/Sanitizing
the BIB Backroom
Package
Weekly cleaning and sanitizing is recommended for the BIB system.
Cleaning and Sanitiz-
ing the Quick Discon-
nect Fittings
To clean and sanitize the BIB quick disconnect fittings, perform the procedure in Table
10.
Cover
Attaching
Screw
Table 10.
Step
Action
1
Remove all the quick disconnects from all the B-I-B containers.
2
Fill a 1-gallon bucket with mild detergent solution.
3
Submerge all disconnects in the soap solution and then clean them using a
nylon bristle brush. (Do not use a wire brush). Rinse them with clean water.
4
Using a plastic pail, prepare approximately five (5) gallons of sanitizing solution.
Summary of Contents for Energize6