CH Series Chiller Operator’s & Installation Manual
Publication Number: 91256
- 4 -
© 2002-2014, Cornelius Inc.
INSTALLATION INSTRUCTIONS
L
OCATION
Locate the chiller indoors in a well ventilated area with ambient temperatures in the range of 65° F to 100° F. Allow a
minimum of six inches of clearance around the chiller for proper air circulation. Avoid hot air discharge from other
equipment or enclosed areas where heat could build up and cause a rise in ambient temperature.
P
LUMBING
Follow standard plumbing practices and local codes in making water connections. Piping that is exposed to high
ambient temperatures may need to be insulated to prevent condensation and/or significant liquid heat gain.
E
LECTRICAL
All wiring must conform to the National Electric Code and any applicable local codes. The chiller must be:
1. Permanently wired by means of conduit from the junction box on the rear of the chiller cabinet to a properly
fused disconnect of proper amperage or;
2.
Wired to a properly rated power cord and plugged into an outlet with appropriate disconnect and amperage
rating.