background image

E

IMI Cornelius Inc; 1998

July 21, 1998

569000242

OBSOLETE

IMI CORNELIUS INC  

g

  One Cornelius Place   

g

  Anoka, MN 55303-6234

Telephone (800) 238-3600                                      Facsimile (612) 422-3246

INSTALLATION INSTRUCTIONS

 VOLTAGE PROTECTOR MODULE KIT (P/N 440000401)

ON

230 VAC, 50Hz VANTAGE POST-MIX DISPENSERS

Read and understand these instructions thoroughly before installing this Voltage Protector Module Kit. Purpose
of the Voltage Protector Module is to shut the Dispenser down should a too low or a too high power voltage con-
dition occur. Retain these instructions as part of your equipment manual.

LOOSE-SHIPPED PARTS

Note: Only qualified personnel should install this Kit.

Unpack and inspect kit. Make sure items are present and in good condition.

Table 1. Loose-Shipped Parts

Item

No.

Part No.

Name

Qty

1

XXXXXXXXX

Voltage Protector Module

1

2

560003334

Electrical Wire (brown)

1

3

560003335

Electrical Wire (black)

1

4

560003336

Electrical Wire (blue)

1

5

325282000

Screw, Hex Washer Hd; Self-Drilling, No. 8–18 Thread by 1/2-inch Long

4

KIT INSTALLATION

WARNING: To avoid possible fatal electrical shock or serious injury to Installer, make sure
Dispenser is disconneced from power source before attempting to install this kit.

1. Disconnect electrical power from the Dispenser

2. Remove screw securing the hood, then lift hood straight up off the Dispenser.

3. Remove two screws securing the electrical control box cover, then remove cover for access to the control

board.

NOTE: It may be necessary to relocate the transformer to make room for installation of the VOLTAGE
PROTECTOR MODULE (item 1) on the refrigeration deck as shown in Figure 1.

4. Remove two screws securing the transformer to the refrigeration deck. Discard the two transformer retain-

ing screws.