Cornelius 2230 C4 Manual Download Page 16

13

91748

Contact your local soft drink or beverage equipment distributor for additional information and

troubleshooting of beverage system.

Trouble

Probable Cause

Remedy

NO PRODUCT DISPENSED

A.

Product tank quick disconnects

not properly connected.

A.

Connect quick disconnects.

B.

No product supply (product

tank empty).

B.

Replenish product supply as

instructed.

C. No CO

2

supply.

C. Replenish CO

2

supply as

instructed.

DISPENSED PRODUCT

COMES OUT OF DISPENSING

VALVE CLEAR BUT FOAMS IN

CUP OR GLASS.

A.

Oil film or soap scum in glass

or cup.

A.

Use clean cups and glasses.

B.

Ice used for finished drink is

sub-cooled.

B.

Do not use ice directly from

freezer. Allow ice to become “wet”

before using. Refer to NOTE.

NOTE:

Ice also causes dispensing problem. When finished drink hits sharp edges of ice, carbonation

is released from drink.

DISPENSING PRODUCT

FOAMS AS IT LEAVES

DISPENSING VALVE.

A.

Product tank CO

2

regulator

adjusted too high.

A.

Adjust product tank CO

2

regulator

to proper equilibrium pressure as

instructed, then replace product

supply.

B.

Dispensing valve restricted or

dirty.

B.

Sanitize product system as

instructed.

C. Tube -- swivel nut

overtightened, distorting nylon

set washer inside -- resulting in

restricted product flow.

C. Replace nylon washer. Make sure

it is properly seated.

D. Oil, water or dirt in CO

2

supply. D. Remove contaminated CO

2.

Clean CO

2

system (lines,

regulator etc.). Install clean CO

2

supply.

Summary of Contents for 2230 C4

Page 1: ...C4 100 2230 C6 100 2230 C4 2230 C6 PRINTED IN U S A IMI CORNELIUS INC 1989 97 Part No 91748 May 1997 Revision C THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood be...

Page 2: ...8 DISPENSER 9 COLD PLATE 9 BEVERAGE SYSTEMS 10 SANITIZE SYRUP SYSTEMS 10 TROUBLESHOOTING 12 BLOWN FUSE OR CIRCUIT BREAKER 12 GATE DOES NOT OPEN 12 GATE DOES NOT OPEN OR IS SLUGGISH AGITATOR TURNS 12 G...

Page 3: ...DIAGRAM BEV CP DISPENSER 14 FIGURE 7 DISPENSER SECTION EXPLODED VIEW 15 FIGURE 8 CABINET SECTION EXPLODED VIEW PARTS LIST 17 FIGURE 9 SOLENOID ASSEMBLY AND PARTS LIST 18 LIST OF TABLES TABLE 1 SPECIFI...

Page 4: ...y broken into small cube sized pieces before filling into the dispenser hopper DESCRIPTION The 2230 series of ice dispensers solves your ice and beverage service needs in the sanitary space saving eco...

Page 5: ...tic rear panel by the inlet of the cold plate and removing the knock out for the drain hose Optional routing through the bottom of the cabinet A Tip unit to the side to access the drain block located...

Page 6: ...t panel from dispenser 3 Remove ice chute and discard gate restrictor 4 Install Ice Diverter as shown 5 Reinstall front panel and energize unit GATE MOUNTING PLATE STORAGE HOPPER ICE DIVERTER ICE CHUT...

Page 7: ...ved entirely for maximum ice flow For glasses and cups the plate may be adjusted downward to reduce the flow of ice The best position depends on the type of ice being used and the size container and m...

Page 8: ...TE 1 18 3 4 4 1 2 14 22 16 1 4 1 1 8 3 15 16 29 3 4 18 25 32 19 3 4 1 1 8 Front of Unit Opening in cabinet bottom for drain beverage hoses Optional location for counter top cut out NOTE Leg mounting l...

Page 9: ...6 91748 FIGURE 4 BEVERAGE SYSTEM PLUMBING DIAGRAM 6 VALVES...

Page 10: ...7 91748 FIGURE 5 BEVERAGE SYSTEM PLUMBING DIAGRAM 4 VALVES...

Page 11: ...overnight or other long periods without ice use Start up the beverage system and adjust faucets to the proper brix Contact your lo cal syrup distributor for complete information on the beverage system...

Page 12: ...inside of the Ice Chute and Ice Chute cover with a mild detergent solution and rinse thoroughly to remove all traces of detergent 9 Reverse steps above to reassemble Ice Chute 10 Sanitize as describe...

Page 13: ...everage faucets 2 Using a suitable pail or bucket fill one with a detergent solution and a second container with a sanitizing solution in the strengths as described in step 1 A Remove the syrup line q...

Page 14: ...g proce dures as described in step 2 then reassemble to the faucet 7 Disconnect the sanitizing tank Hook up the product tank to the unit and to the CO2 system Energize the fau cet to flush the sanitiz...

Page 15: ...bable Cause BLOWN FUSE OR CIRCUIT BREAKER A Short circuit in wiring B Defective gate solenoid C Defective agitator motor GATE DOES NOT OPEN A No power B Bent depressor plate does not actuate switch C...

Page 16: ...ub cooled B Do not use ice directly from freezer Allow ice to become wet before using Refer to NOTE NOTE Ice also causes dispensing problem When finished drink hits sharp edges of ice carbonation is r...

Page 17: ...14 91748 FIGURE 6 WIRING DIAGRAM BEV CP DISPENSER WHEN REPLACING SOLENOID ADJUST TO 7 8 IN AS SHOWN BEFORE TIGHTENING MOUNTING SCREWS...

Page 18: ...15 91748 34 33 32 31 6 15 17 5 1 2 4 17 16 12 11 14 13 8 7 10 20 21 19 18 22 23 25 3 28 29 9 30 FIGURE 7 DISPENSER SECTION EXPLODED VIEW...

Page 19: ...996 Panel S S Merchandiser 16 27638 Splash Panel 17 10145 Sink Mtg Pin 18 70545 Clamp 19 51775 Flexible Drain Fitting 20 51801 Cold Plate Drain Insulation 21 52049 Drain Insulation 22 27470 Mounting B...

Page 20: ...or Timer 5 30774 Capacitor 6 51891 Gate Gasket 7 53015 Ice Chute Back Section 8 53016 Ice Chute Cover 9 50842 Motor Plate Insulation 10 51860 Motor Gasket 11 51859 Motor Shaft Seal 12 32498 Agitator M...

Page 21: ...ate Lift Rod 9 10081 1 Gate Lift Rod Bushing 10 50754 1 Gate Arm Bearing 11 21492 1 Gate lift Arm 12 70043 1 Flatwasher 13 70422 1 Spring 14 70263 1 1 4 20 x 3 4 Hex Hd Screw 15 70048 1 1 4 Lockwasher...

Page 22: ...O DE JANEIRO BRAZIL D 55 21 591 7150 D FAX 55 21 593 1829 ENGLAND D TYTHING ROAD ALCESTER D WARWICKSHIRE B49 6 EU ENGLAND D 44 789 763 101 D FAX 44 789 763 644 FRANCE D 71 ROUTE DE ST DENIS D F 95170...

Page 23: ...One Cornelius Place Anoka Minnesota 55303 6234 612 421 6120 800 238 3600 Corporate Headquarters IMI CORNELIUS INC...

Reviews: