background image

Operator manual

Undercounter cooler

Energize 1 HC

Summary of Contents for 221001100

Page 1: ...Operator manual Undercounter cooler Energize 1 HC...

Page 2: ...d utilisation of this document as well as the communication of its contents is prohibited unless expressly permitted Violations shall result in an obligation to pay damages All rights reserved with re...

Page 3: ...5 2 Safety information to prevent personal injury and equipment damage 8 2 Handling the Unit Prior to Installation 10 2 1 Unpacking the unit 10 2 2 Storage 11 2 3 Disposal 12 3 Description 13 3 1 Asse...

Page 4: ...no TD1001000 Version 01 10 2019 Index 4 Operator manual Undercounter cooler Energize 1 HC 2 6 Errors and malfunctions 24 6 1 Troubleshooting table 24 7 Applicable documents 27 7 1 Declaration of confo...

Page 5: ...lation is to be carried out by an expert in compliance with all of the specifications given in the installation and service manual see the document Undercounter cooler installation and service manual...

Page 6: ...ing and maintenance work must not be carried out by children unattended Use by those under the influence of medication alcohol drugs or other substances which impair their physical sensory or mental a...

Page 7: ...and be ex pressly charged with its use This document is to be available to staff at all times If this unit is openly accessible and set up so that untrained staff can use it the operator is to provide...

Page 8: ...high risk2 which results in serious injuries or death if not avoided WARNING marks a danger with a medium risk2 which may result in serious injury or death if not avoided CAUTION marks a danger with...

Page 9: ...nties If work is undertaken on the unit which is not described in this document Cornelius Deutsch land GmbH shall not assume any liability for any resulting hazards and damages The same applies to des...

Page 10: ...unit after it has been in continuous use over an ex tended period of time will result in a risk of burns Take appropriate safeguard measures such as by wearing heat resis tant protective gloves DANGE...

Page 11: ...ir and consequently accu mulates at the bottom and may enter lower lying areas e g sewage sys tems At high concentrations this may lead to a lack of oxygen resulting in a risk of suffocation Lower con...

Page 12: ...any claim 1 Inspect the cardboard box and make a note of any damage however minimal this may seem If the cardboard box is damaged please make a note of the following on the copy of your freight invoi...

Page 13: ...e ambient conditions If possible store the unit in its original packaging Unpacked units must be covered with a dustproof cover No condensate must form under the cover ATTENTION Risk of electrostatic...

Page 14: ...water or cleaning agent residue remaining inside the unit This will lead to damage to internal components Before shipment storage or relocation of the unit the unit is to be cleaned and the cleaning s...

Page 15: ...Undercounter cooler Energize 1 HC 13 3 Description 3 1 Assemblies and components The unit comprises the following assemblies Fig 1 1 2 3 4 6 5 1 Cover 2 Connecting plate with tube connections 3 Contro...

Page 16: ...lled to the right temperature in the housing Drinking water is also carbonated This means that still water soda and chilled syrup are available at the re frigerator outlets for postmix beverages When...

Page 17: ...service manual contains the diagram and description of the connections for this unit see the document Undercount er cooler installation and service manual document no TD1001100 Description Parameter V...

Page 18: ...res NOTICE When using Cornelius pythons heat loss of 8 15 kcal h is to be calculated for each consecutive metre 2 3 4 5 1 1 Dangerous voltage warning sign 2 Python connection warning sign 3 Refrigeran...

Page 19: ...injury or equipment damage Please always strictly observe all safety measures and information in structions see chapter 1 The unit has been designed for continuous operation Apart from the daily check...

Page 20: ...e water pressure is set as specified for the setpoint see chapter 3 3 8 Check the fill level and the connection of the syrup containers and BIBs and replace the empty containers with full ones see cha...

Page 21: ...hat needs changing 2 Exchange the empty product container for a full one and remove the protective cap from its connection NOTICE Do not mix up standard and light products as they are conveyed with di...

Page 22: ...be carried out by an expert see chapter 1 3 3 as the unit has to be cleaned and drained 1 Close the CO2 bottle valve see documentation on the CO2 system 2 Close the CO2 shut off valves see documentati...

Page 23: ...ns see chapter 1 5 1 Maintenance table NOTICE The following table provides information on recommended maintenance in tervals to be adapted to the relevant installation situation Interval Components Ac...

Page 24: ...ressure for pressurising the syrup pumps is set as specified for the setpoint see chapter 3 3 5 Check that the CO2 shut off valves are open see documentation on the CO2 system If necessary open the CO...

Page 25: ...ed see chapter 5 3 14 Check the legibility of the warning signs see chapter 3 3 3 Always replace any missing or illegible warning signs Please contact your service partner Fig 9 Required tools materia...

Page 26: ...not running Switch on the compressor see chapter 4 1 Please contact your service part ner Beverage is too warm and the com pressor is running Excessive beverage dispensing Do not exceed the maximum d...

Page 27: ...off valve or pressure reduc ing valve for the fresh water supply is closed Open the shut off valve and pres sure reducing valve for the fresh water supply see documentation on the drinking water syst...

Page 28: ...th sharp edged ice CO2 is released from the dispensed drink Insufficient amount of CO2 in the bever age CO2 pressure for soda is set incor rectly on the relevant pressure re ducing valve Correctly adj...

Page 29: ...pplicable documents Cornelius Deutschland GmbH Document no TD1001000 Version 01 10 2019 Index 4 Operator manual Undercounter cooler Energize 1 HC 27 7 Applicable documents 7 1 Declaration of conformit...

Page 30: ...RI WKH SODFH RI RSHUDWLRQ 1DPH RI WKH SODFH RI RSHUDWLRQ 6WUHHW DGGUHVV KRXVH QR 3RVWFRGH WRZQ 1DPH RI WKH RSHUDWRU 2SHUDWRU FRS 7KH RSHUDWRU KDV EHHQ LQVWUXFWHG LQ WKH XVH RI WKH XQLW DWH 6WDPS DQG V...

Page 31: ...anual Undercounter cooler Energize 1 HC 29 QVWDOOHU FRS 7KH RSHUDWRU KDV EHHQ LQVWUXFWHG LQ WKH XVH RI WKH XQLW DWH 6WDPS DQG VLJQDWXUH 2SHUDWRU 6WDPS DQG VLJQDWXUH QVWDOOHU RI WKH XQLW 7KH XQLW KDV E...

Page 32: ...WHG RQ WKH IROORZLQJ WRSLFV HQHUDO VHTXHQFH RI RSHUDWLRQV 5HIHUHQFH WR H LVWLQJ GRFXPHQWDWLRQ OHDQLQJ WKH XQLW DVW QDPH ILUVW QDPH 6LJQDWXUH DVW QDPH ILUVW QDPH 6LJQDWXUH DVW QDPH ILUVW QDPH 6LJQDWXUH...

Page 33: ...s Deutschland GmbH Document no TD1001000 Version 01 10 2019 Index 4 Operator manual Undercounter cooler Energize 1 HC 31 5 Date Component alkaline acidic Chemical agent Cleaning agent Carried out by S...

Page 34: ...www cornelius emea com Cornelius Deutschland GmbH Carl Leverkus Str 15 40764 Langenfeld Germany Tel 49 0 21 73 79 3 0 Fax 49 0 21 73 77 4 38 E Mail info cornelius com...

Reviews: