10
Troubleshooting Guide
Corinex AV CableLAN Adapter
Troubleshooting Guide
The
Corinex AV CableLAN Adapter
has been designed to be a reliable and easy to use network
connection device. Please refer to the list below to aid in troubleshooting.
The POWER LED is off.
1. Verify the connection of the power cable to the device’s power inlet.
2. Make sure that the power adapter is properly plugged into the electrical socket.
3. Try to use another socket.
The LAN (Ethernet) Link/Act LED is off.
1. Make sure that the Ethernet cable is correctly plugged into the Ethernet port.
2. The Ethernet-enabled device, to which the adapter is connected, should be
powered on and properly configured.
3. Try to use another Ethernet cable.
The HCNA Link/Act LED is off.
1. Make sure that the coaxial cable is correctly plugged into the HCNA port.
2. The HCNA device, to which the adapter is connected, should be powered on and
properly configured.
3. Try to use another coaxial cable.
4. Ensure that all devices which should communicate, are on the same coaxial cable
and there is no one-way signal amplifier in the way.
The HCNA SyncMode LED is off.
1. Make sure if the bridge beside xDSL Modem is set as “Master” by setting the Bit-1
of DIP Switch as “Lo” before POWER ON. Other devices should be set as “Slave”
– Bit-1 as “Hi”.
2. “SyncMode” LED, on the Master will be always ON. “SyncMode” on a Slave will
be OFF unless there is a Master detected on the coaxial cable.
3. The Ethernet or HCNA device to which you are connected should be powered on
and properly configured.
4