CoreTigo TigoBridge A1 User Manual Download Page 1

Copyright © 2021 CoreTigo Ltd.

 

TigoBridge A1 

User

 

Manual

 

 

 

 

 

 

 

 

 

CoreTigo

  

TigoBridge A1 

 

U

SER 

M

ANUAL

 

 

 

 

Summary of Contents for TigoBridge A1

Page 1: ...Copyright 2021 CoreTigo Ltd TigoBridge A1 User Manual CoreTigo TigoBridge A1 USER MANUAL...

Page 2: ...TigoBridge A1 User Manual Copyright 2021 CoreTigo Ltd Page 2 of 23...

Page 3: ...ion 8 4 2 Overview 8 4 2 1 Functional Diagram 9 4 3 LEDS 9 4 3 1 Power LED 9 4 3 2 Status LED 10 4 4 Pair by Button 10 4 5 Electrical Wiring 10 4 6 Electrical Connection 11 5 Mounting 11 5 1 TigoBridg...

Page 4: ...c Diagram 11 Figure 7 Cradle Dimensions 11 Figure 8 TigoBridge A1 and Cradle 12 Figure 9 TigoBridge A1 Mounted on the Cradle 12 Figure 10 TigoEngine Scanning Mode 13 Figure 11 TigoEngine Pairing Proce...

Page 5: ...igo Ltd Page 4 of 23 Acronyms and Abbreviations Acronyms and abbreviations used in this document are listed in this table Symbol Meaning FW Firmware HW Hardware IF Interface IOLW IO Link Wireless LED...

Page 6: ...ure 1 TigoBridge A1 References TigoEngine User Manual TigoMaster 2TH User Manual 1 1 Structure The sections of this user manual build on one another 1 2 Typographical Conventions Enumerations are show...

Page 7: ...ode NEC NFPA 70 Clause 725 121 and Canadian Electrical Code CEC Part I C22 1 2 3 Intended Use The TigoBridge A1 is an IO Link Wireless Class A Bridge with an IP67 enclosure The TigoBridge A1 is intend...

Page 8: ...TigoBridge A1 is implemented based on the IO Link Wireless standard for W Bridge devices TigoBridge A1 is part of an IO Link Wireless environment It communicates with an IO Link Wireless master There...

Page 9: ...ing an M12 cable TigoBridge A1 can be connected to an IO Link Wireless Master by TigoEngine Integrated web server tool or PLC Each IO Link Wireless master can operate up to 16 TigoBridges A1 4 2 Overv...

Page 10: ...igure 4 TigoBridge A1 Functional Diagram A Device Connector B Pairing Button C Power Supply Connector D Power LED Green E Status LED RGB 4 3 LEDS Figure 5 TigoBridge A1 LEDs A Status LED RGB B Power L...

Page 11: ...y button is used to replace existing TigoBridge A1 with a new one The TigoBridge A1 must be powered off to assure that the TigoMaster disconnects before installing a new TigoBridge A1 Pairing Button c...

Page 12: ...5 Mounting TigoBridge A1 should be mounted safely and securely next to the device to which it is connected TigoBridge A1 can be mounted with or without the cradle accessory 5 1 TigoBridge Cradle The...

Page 13: ...onnected to PC Installation 1 Plug a 24VDC power supply to TigoBridge A1 M12 power connector via M12 cable 2 The Power LED lights up green If it does not check the power connection 3 Once the power su...

Page 14: ...ted TigoBridge A1 Select an empty port on the Master side and click Pair Figure 11 TigoEngine Pairing Process 8 When the pairing process is complete the TigoEngine Port Mode should indicate OPERATE Th...

Page 15: ...tton on the TigoEngine interface and repeat the instructions to unpair it Once unpaired the TigoBridge A1 status LED alternates between magenta and green Figure 14 Unpair Button 7 Firmware Update Firm...

Page 16: ...perational Alternating Blue and Green Alternating Magenta and Green Non Operational Alternating Blue and Yellow Alternating Magenta and Yellow Alternating Blue and Green fully Operational both IO Link...

Page 17: ...t the interference at his own expense 9 3 Modification Statements FCC Warning Modification statement CoreTigo LTD has not approved any changes or modifications to this device by the user Any changes o...

Page 18: ...y RF Exposure rules This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Le pr sent appareil est conforme l exposition aux radiations FCC ISED d fi...

Page 19: ...ces LEDs IO Link RGB three color LED Power Green color LED Button Pairing external push button Connectors Input connector Plug M12 A coded power Connector o Pin number 1 Input L Power supply o Pin num...

Page 20: ...0068 2 27 Bumps IEC 60068 2 27 TigoBridge A1 should be supplied from a limited Class 2 power supply or via overcurrent protective device fuse breacker etc rated 4A max Over current protection on L For...

Page 21: ...Copyright 2021 CoreTigo Ltd Page 20 of 23 Immunity EN 61000 6 2 o EN31000 4 2 Electrostatic discharge o EN61000 4 4 Fast transients burst o EN61000 4 5 Surge immunity o EN61000 4 6 Conducted immunity...

Page 22: ...TigoBridge A1 User Manual Copyright 2021 CoreTigo Ltd Page 21 of 23 11 Customer Support For any issue question or to report a bug contact support coretigo com...

Page 23: ...A Part Number Part number CT221 0057 03 Generation 2 Product Identifier 2 Product Type 1 Protocol 0057 Characters Identifier of Features Version 03 CT GXY ZZZZiii vv G X Y ZZZZ iii vv Generation Prod...