QUICKGUIDE TO ACCESS CONTROL INSTALLATION

Model 2003

One Door Control

n  

n  

n  

n  

n  

n  

n  

n  

n  

n  

One door access control

Supports one card reader and one keypad

Battery Backup: 4 Amp/hr for 15 hours of backup time

Power Requirements: 16.5VAC @ 40VA transformer with standby battery

Supports Bar Code, Data Chip, Mag-Stripe, Proximity and Wiegand card technologies

Memory Backup: 3 VDC lithium battery for a minimum of 30 days memory backup

One Door Relay:  Form C and Form A contact rated 5A @ 30 VDC

One Auxiliary Relay:  Form C contact rated 5A @ 30 VDC

One Voltage Output:  Switches low (-) 50 ma

One Sh

unt Contact and One Zone Input

n  

26/30-bit Wiegand card formats

Model 2016

Two Door Control

n  

n  

n  

n  

n  

n  

n  

n  

n  

n  

Two door access control

Supports two card readers and two keypads

Battery Backup: 4 Amp/hr for 15 hours of backup time

Power Requirements: 16.5VAC @ 40VA transformer with standby battery

Supports Bar Code, Data Chip, Mag-Stripe, Proximity and Wiegand card technologies

Memory Backup: 3 VDC lithium battery for a minimum of 30 days memory backup

Two Door Relays:  Form C and Form A contact rated 5A @ 30 VDC

Two Auxiliary Relays:  Form C contact rated 5A @ 30 VDC

Two Voltage Outputs:  Switches low (-) 50 ma

Two Shunt Contacts and Two Zone Inputs

n  

26/30-bit Wiegand card formats

System 2

n  

n  

n  

n  

n  

n  

n  

n  

Networks up to 16 doors

Each unit Supports 485 users

Add up to 6,000 users later

Start with one Door now, add more later

Built-in programming or use your PC

Easy off-site set-up & reporting

Reliable distributed system

Built-in printer output

For further assistance, call (800) OK CORBY

Summary of Contents for SYSTEM 2

Page 1: ...access control systems QUICKGUIDE TO SYSTEM 2 ACCESS CONTROL INSTALLATION...

Page 2: ...trol n n n n n n n n n n Two door access control Supports two card readers and two keypads Battery Backup 4 Amp hr for 15 hours of backup time Power Requirements 16 5VAC 40VA transformer with standby...

Page 3: ...ire a different conductor wire 5 conductor 22 gauge shielded 500 feet maximum 67005 The wire length can be increased using an extender module 8 conductor 22 gauge shielded 1000 feet maximum 67007 6 co...

Page 4: ...eader For further assistance call 800 OK CORBY 5 conductor 22 gauge shielded 500 feet maximum 67005 The wire length can be increased using an extender module 8 conductor 22 gauge shielded 1000 feet ma...

Page 5: ...RT NUMBERS AND WIRE SPECIFICATIONS If using a door strike to secure the door a Request To Exit button may not be necessary BOLD Outdoor Version E DOOR 1 DOOR 2 For further assistance call 800 OK CORBY...

Page 6: ...feet maximum from first unit to last unit 93302 4126 PC or Modem PC runs using standard terminal emulation software 5 conductor 22 gauge shielded 100 feet maximum 67005 4412 PC 4100 Video Display Ter...

Page 7: ...mount with bi color LED back lit read head and mounting hardware 4320Chip assembled on a key ring with Corby logo 4321Chip Only For use with badges photo ID cards etc 4323Roll of double stick tape do...

Page 8: ...tacts rated 5 a mps 30 VDC Red and Green LED indicator The following additional outputs will be provided for signaling shunt and schedule control Two form C relays rated five amps 30VDC and two voltag...

Reviews: