14
CL33600 Series Cylindrical Lock
Copyright © 2009 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
Typlcal CL33600 x M812 Series Lock Application Diagram (12/24VDC Lock)
DIAGRAM #2 – MODE 2: LED WIRE TIED TO GROUND = GREEN LED ‘ON’ WHEN POWERED
6) Wiring Diagrams (Continued)
QC12
Electric Hinge
Power Supply
(By Others)
Electrical Access
Control Panel
(By Others)
Use (NC) for Fail
Safe Operation
Lock Relay
(NO) Fail Secure
Operation
DPS
DPS
DATA 1
DATA 0
RX (NO)
RX (COM)
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
*EARTH GROUND - Brown, 7
LED - Yellow, 8
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
Door
Position
Switch
12 / 24 VDC
H N G
- +
120 VAC
Input
Black (Hot)
White (Neutral)
Gr
een (Gnd)
12 Conductor
ElectroLynx Harness
White (C)
Gr
een (NC)
Access 600 Reader Requires
12 or 24 VDC Power
CL33600
Series Lock
12/24VDC SYSTEM
Reader Draw = 125mA
12VDC Solenoid Draw = 250mA
12VDC Total Current Draw = 375mA
24VDC Solenoid Draw = 150mA
24VDC Total Current Draw = 275mA
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.