5) Installation Instructions (Continued)

Standard Cylinder Installation

Make sure cylinder tailpiece is aligned in same direction as cylinder bible.  
Slide cylinder all the way into the lever.

For 6-pin cylinder: Fold retainer at hinge and press fit retainer halves together as shown.

For 7-pin cylinder: Break retrainer at hinge and discard spacer section. Also remove 
black cylinder spacer from inside of chassis follback for clearance. 

10.   Install Wire Cover Plate:

Install the wire cover plate to the inside of the door above the lock body (Fig 9a).  
Be careful not to pinch the wires when securing the cover plate.
Note: Wire cover is only required for wood doors  
with the wire run channel on inside face of door. 

Fig.  9b Detail

Fig. 9b

Inside Face of Door

Wire Cover

(2) #6 x 1/2”
Flat Head Security
Torx Wood Screws

This Side Down

Back Side of Wire 

Cover Plate

Door Status Switch

9.  

Installation and Removal of Lever and Standard Cylinders (continued): 

Fig.  9a

(2) 3/32” Diameter  

by 1/2” Deep Holes

Harness from 

Lock Body

Summary of Contents for Access 700 CL33700 TCPIP1 Series

Page 1: ...mportant The accuracy of the door preparation is critical for proper functioning and security of this lock Misalignment can cause premature wear and a lessening of security For Technical Assistance ca...

Page 2: ...he radio certification number only signifies that Industry Canada technical specifications were met This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment...

Page 3: ...for pairs of doors Deadlocking latch prevents manipulation when door closed Door Thickness 1 3 4 44mm to 2 50mm Standard Optional 2 50mm to 2 1 4 57mm optional Outside lever controlled by keypad magst...

Page 4: ...by Mag Swipe and Keypad 784585 FIN Outside Escutcheon Assemby Mag Swipe Keypad HID 125kHz Prox and 13 56 MHz Prox 784595 FIN Outside Escutcheon Assemby Mag Swipe HID 125kHz Prox and 13 56 MHz Prox 784...

Page 5: ...Wrench supplied 7 64 Allen Wrench supplied T20 Security torx driver supplied 1 783F918 CL33134 Cylindrical lock with fixed core cylinder 1 783F928 CL33134 Cylindrical lock with removable core cylinde...

Page 6: ...anufacturer templates visit www corbinrusswin com and reference Template T31077 Left Hand Hinges Left Open Inward LH Left Hand Reverse Bevel Hinges Left Open Outward LHRB Right Hand Hinges Right Open...

Page 7: ...the express written permission of Corbin Russwin Inc is prohibited 5 Installation Instructions Continued 3 Install Latch Bolt Install using two 8 x 3 4 combination screws Fig 3 Note Make sure the beve...

Page 8: ...or in place in the frame c Insert connector end of DPS harness through raceway on latch edge of door Fig 5c Note Use collar in METAL door only d Push door status switch firmly into place by hand Impor...

Page 9: ...ig 7a d Run wires through slots in edges of spring cassette Fig 7b Note Do not run wires through center hole and be careful not to pinch wires under spring cassette There are DOOR EDGE markings on the...

Page 10: ...ted Fig 8 8 Connect cables Connectors go on one way Each connector is mated to prevent connecting incorrectly a Connect 2 pin wire to Door Status Switch b Connect 4 pin connector from harness into wir...

Page 11: ...7 pin cylinder Break retrainer at hinge and discard spacer section Also remove black cylinder spacer from inside of chassis follback for clearance 10 Install Wire Cover Plate Install the wire cover p...

Page 12: ...gasket along the edge of the outside escutcheon assembly Fig 10 Fig 11b DPS Reader Cable Mounting Plate Position ground ring terminal upright then tighten screw Lock body cable a Insert the mounting p...

Page 13: ...external 9 24VDC power connector 11 Installation of Connectors Secure the following connectors to their respective terminals Fig 12a b a Secure the 2 pin DPS connector b Secure the 10 pin lock body a...

Page 14: ...a Insert bottom tab of controller into slot on mounting plate Fig 12a b b Looking down from top of controller ensure proper alignment of board to board connectors Fig 12b while pivoting controller tow...

Page 15: ...then an audible beep will sound and the lock motor will cycle For battery replacement When replacing the 6 AA alkaline batteries in the compartment please note batteries must be replaced within five 5...

Page 16: ...eserved Reproduction in whole or in part without the express written permission of Corbin Russwin Inc is prohibited Important Note Wiring Installation If you are installing PIP PoE please go to Page 1...

Page 17: ...from harness to end user provided facility cable Supplied by End User PoE Switch PoE Lock Ceiling Supplied by CI C B A PoE Patch Panel Drain Wire Terminated on Rack D Ground Ring Terminal Secured to L...

Page 18: ...end ceiling side PoE harness TIA EIB 568 B Standard Wiring 1 2 3 4 5 6 7 8 Pair Number Wire PIN 1 White Blue White Blue 5 Blue 4 2 White Orange White Orange 1 Orange 2 3 White Green White Green 3 Gre...

Page 19: ...Order of installation may vary Refer to appropriate sections for instructions 1 Prop door open 2 Tape the two lock side 4 pin connectors to the ring terminal 3 Using the ring terminal carefully fish...

Page 20: ...to eliminate issues b The key should retract the latch and the key should rotate freely c The key should extend and retract the deadbolt For units without a keypad add card using LCT software and tes...

Page 21: ...yright 2014 Corbin Russwin Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Corbin Russwin Inc is prohibited 700 TCPWI1 TP...