background image

TUBULAR SHOWER PANELS

PAGE 1

00 71277 00 / Issue 6 / 10

Please read these instructions carefully and keep for future reference. 
Incorrect fitting will invalidate the guarantee.

SAFETY

● 

Handle glass with care. Sharp impacts can damage the metal components and 
could shatter the glass.

 Do not remove the plastic corner protectors from the glass panels until the panels 

are about to be fitted.

● 

As the parts are large, we recommend that two people are needed to carry out  
parts of the installation.

● 

Make sure there are no hidden pipes or cables in the floor and walls where you 
intend to drill.

● 

Wear safety goggles, shoes and appropriate clothing.  

BEFORE INSTALLATION

● 

The enclosure will not sit correctly on an uneven surface. If uneven, the wall 
channels may not fit. 

● 

Note:

 

If not fitted on a tray, ensure the enclosure is fitted to a tiled or 

waterproof composite floor.

● 

The enclosure should be fitted on tiled walls which are sealed with waterproof grout. 

● 

Always check very carefully that components are vertical.

● 

To avoid damage, use the opened out packaging to build the enclosure on.

EQUIPMENT NEEDED:

Drill, 6mm Masonry Bit, 3mm Metal Bit (general), Crosshead Screwdriver, Spirit Level, 
Pencil, Fine Tooth Saw, Silicone Sealant, Scissors, Tape Measure.

Note: The screws and wall plugs supplied are for masonry walls. For lightweight  
walls i.e. stud partitions, plasterboard etc, use the correct type of fixings.

SINGLE PANEL - PAGES 2 - 4

DOUBLE PANEL - PAGES 4 - 9

2

1

2

1

2

1

1

1

2

1

4

2

2

1

2

1

2

1

10

5

4

2

PANELS:

2

1

2

1

10

5

10

5

PN60159 

Grub screw

PN50247 

Top cap

PN60162 

3mm  

Allen key

PN80456

Outer  

ceiling bracket

Assemble

PN60154 

Strut  

bracket 

PN60210

 

Wall plug

PN40063 

Seal

PN60320 

16mm

Screw

PN60312 

38mm

Screw

PN8212 

Washer

CUSTOMER CARELINE: 01746 713410

Check contents of the pack before installation. If there is anything missing, contact our Customer Care Number for assistance. 

The fixings may be spread across several packs - please check the contents of each pack carefully. 

PANELS:

PANELS:

PANELS:

PANELS:

2

1

2

1

2

1

PN60163

Tube cap

PN80480

Panel 

bracket/

Glass clamp

PANELS:

Vertical Strut Option

Vertical Strut Option

Summary of Contents for TUBULAR SHOWER PANELS

Page 1: ... check very carefully that components are vertical To avoid damage use the opened out packaging to build the enclosure on EQUIPMENT NEEDED Drill 6mm Masonry Bit 3mm Metal Bit general Crosshead Screwdriver Spirit Level Pencil Fine Tooth Saw Silicone Sealant Scissors Tape Measure Note The screws and wall plugs supplied are for masonry walls For lightweight walls i e stud partitions plasterboard etc ...

Page 2: ...ix the wall channel to the wall If necessary slight adjustment is available in the wall channel b a c 5 Assemble the strut slide on the panel bracket and wall bracket assembly Lightly tighten the fitted grub screws Carefully place the strut assembly onto the glass approximately 100mm from the edge depending on your installation Ensure the strut is level and mark the position of the wall bracket as...

Page 3: ...onto the glass panel with grub screws on the inside Screw the wall bracket cover onto the inner wall bracket f Tighten the wall bracket cover grub screw g From inside slide the glass clamp up between the bracket and glass panel tighten the grub screw 1 Ensure the panel is vertical and tighten the grub screw Push fit the top cap onto the top of the wall channel 9 Ensure that the opening end of the ...

Page 4: ...nsert the wall plug and fix the inner ceiling bracket to the ceiling using a 32mm screw and washer Note The opening in the inner ceiling bracket should be parallel with the end of the panel Note The screws and wall plugs supplied are for masonry walls For lightweight walls i e stud partitions plasterboard etc use the correct type of fixings 13 a Reposition the strut back onto the panel with grub s...

Page 5: ...on Max opening 800mm c IMPORTANT Ensure Glass Guard H2o label is to the outside of the enclosure panel Satin glass patterns must be installed to the outside of the enclosure Note The Glass Guard coating is on the opposite side to the label or satin glass patterns ONLY Horizontal strut installation 4 a Ensure that the opening end of the panel is vertical and the panel is parallel with the opposite ...

Page 6: ... the marked position and mark the fixing hole onto the wall b Drill the position marked using a 6mm drill bit 30mm deep c Insert the wall plug and fix the inner wall bracket to the wall using a 38mm screw and washer Note The screws and wall plugs supplied are for masonry walls For lightweight walls i e stud partitions plasterboard etc use the correct type of fixings d Slide the strut bracket and w...

Page 7: ...nels Outside 12 Ensure that the end of the second panel is vertical Carefully place the second panel bracket on to the glass approximately 100mm from the edge depending on your installation Carefully measure the distance Y between the wall bracket assembly and the panel bracket Y Position the strut into the wall bracket assembly and the panel bracket Ensure the panel is vertical and tighten the gr...

Page 8: ...tallation Ensure the strut is vertical and mark the position of the outer ceiling bracket onto the ceiling c Remove the strut assembly Drill a hole in the centre of the position marked using a 6mm drill bit 30mm deep d Insert the wall plug and fix the inner ceiling bracket to the ceiling using a 32mm screw and washer Note The opening in the inner ceiling bracket should be parallel with the end of ...

Page 9: ...ntact your local authority to find your nearest recycling centre 22 Place the second wall channel in position against the wall a Ensure the wall channel is vertical and mark the four holes onto the wall b Drill the four positions marked using a 6mm drill bit c Apply silicone sealant to the back of the wall channels d Insert the wall plugs Place washers over the 32mm screws and fix the wall channel...

Reviews: