Equipment needed: 

Drill, 6.5mm Masonry Bit, 4.5mm & 3mm Metal Bits (general), Crosshead Screwdriver, Large Flatblade Screwdriver,  
Right Angle, Fine Tooth Saw, Spirit Level, Scissors, Pencil, Silicone Sealant, Tape Measure, Masking Tape.

Note:

 The screws and wall plugs supplied are for masonry walls. For lightweight walls i.e. stud partition, plasterboard etc, 

use the correct type of fixings.

Please read these instructions carefully and keep for future reference. 

Incorrect fitting will invalidate the guarantee.

 SAFETY

● 

Handle glass with great care.  

  Although the glass is very tough, sharp impacts can damage both the glass and metal frame.

● 

Make sure there are no hidden pipes or cables hidden in the wall where you intend to drill.

● 

Wear safety goggles, shoes and appropriate clothing.

 BEFORE INSTALLATION

● 

Check that the shower tray is level in all directions. The enclosure will not sit correctly on an uneven surface.  

  If uneven, the wall channels may not fit and the doors may not shut correctly.

● 

The enclosure should be fitted on tiled walls which are sealed with waterproof grout. 

  There must be a good silicone seal between the rim of the shower tray and the wall.

● 

The shower tray and the enclosure must match in size. Attempting to fit the incorrect size of enclosure to  

  the shower tray will result in water leaks.

● 

Always check very carefully that components are vertical.

● 

To avoid damage, use the opened out packaging to build the enclosure on.

OPTIMA CORNER ENTRY  

SHOWER ENCLOSURE

CUSTOMER CARELINE 01746 713410

Doors may need adjusting (as in 

a

b

 & 

c

) so they are square, meet in the middle and slide freely.  

(

a

) Loosen top hanger screws (1 turn maximum) on doors. (

b

) Rotate top mouldings until bottom mouldings hook under bottom 

rail. (

c

) Rotate top mouldings to lift doors back up (with bottom sliders hooked under rail), re-tighten hanger screws.  

Fit covers caps onto top and bottom mouldings. 

c

b

a

7

(

a

) Push-fit threshold strip (PN40093) in to top and bottom rails. Cut to length, ensuring they fit up to corner mouldings.  

(

b

) Lubricate inner top and bottom rails with wipe provided.

8

From the outside only

, apply 

sealant to the bottom of the 
enclosure and 50mm up the wall 
channels as shown.

9

 CARE AND MAINTENANCE

IMPORTANT: 

You must not use the shower for 24 hours after installation of the enclosure.

DO NOT

 use bleach, scouring powders, solvents or other aggressive cleaning agents. To clean, use warm soapy water and a  

clean cloth and rinse off.

Periodically check all fixings and fittings and tighten if necessary.