- 8 -
Typical settings for 740 & 760 softeners,
Vessel Size
613 1012 817 822 919 735 1023 835 935 1035
Media Volume to program (litres)
5
10
10
15
15
20
20
20
30
35
Time of day (HH:MM)
P1
Day of week (DAY)
P2
Time of regeneration (HH:MM)
P3
Calendar override days 740
P4
3
3
3
3
3
3
3
3
3
3
Calendar override days 760
P4 14
14
14
14
14
14
14
14
14
14
Regen interval if P4 set to 0 (740 ONLY)
P5
Salt amount (gms)
P6
H
H
H
S
S
S
S
S
S
S
Capacity (Kg) 740 control (cannot change)
P7 0.3
0.5
0.5 0.8 0.8 1.2
1.2
1.5 1.6
2.1
Capacity (Kg) 760 control
P7 0.2
0.5
0.5 0.7 0.7 0.9
1.1
1,3 1.5
1,8
Hardness in ppm CaCO3
P8
Set on site 760 only
Set on site
Set on site
Set on site / Factory set default 2.00am
Set on site if required
4202035013
SNo 08090137
Mis
0919-255-760
To Re Set the Control
Only to be done when necessary.
1.
Press and hold SET and DOWN together for 5 seconds.
2.
H0 and the system’s resin volume for model will be displayed.
3.
Press and hold the square set button for 5 seconds, three dashes should
then appear on screen.
4.
Use the up or down arrows to select the correct or nearest media volume
of your softener.
5.
Press the set button to accept this setting.
6.
Refer to the earlier set up guide for the other settings.
Identifying your Softener.
Your softener will have a identification label fixed to the outer carton and the control valve,
this will look similar to the picture shown here.
The information listed can be read as follows:
Stock Number:
Manufacturers part number.
Serial No:
Serial No.
Id Code:
Softener type identification code.
Configuration:
Vessel size, Valve type & Controller type.
Identify the settings relevant to your softener from the chart below by looking at the vessel
size and controller type.
Soft 001a