![CORA CS1040 User Manual Download Page 16](http://html1.mh-extra.com/html/cora/cs1040/cs1040_user-manual_2666382016.webp)
CS1010 Long Range Vibration Sensor – User Guide
Page 16
Configuration and Integration
The CS1040 supports the following settings and features, which are configured via downlink
messages.
Configuration
Description
Units
Default
Vibration
Notification
Reminder Interval
How often the vibration reminder
notification is uplinked.
minutes
10
Vibration
Notification
Reminder Count
The maximum count of reminder
notifications after the vibration is
detected.
count
0xFFFF
Heartbeat / Battery
Interval
Specifies the heartbeat message
uplink interval
minutes
180
(3 hours)
Statistics Interval
How often the statistics are uplinked.
minutes
0: disabled
Clear Statistics
Downlink this message to clear the
stored statistics
N/A
N/A
LED Mode
•
LED OFF (Stealth Mode)
•
LED ON (Telemetry Only)
•
LED ON (Sensor and Telemetry)
N/A
LED ON (Sensor
and Telemetry)
Notification Confirm
/ Unconfirmed
Setting
If set to true, vibration notifications are
confirmed uplink messages. Set to
false to uplink without confirmation.
N/A
CONFIRMED
MESSAGES
Notification Enable
Enable or Disable notifications. If
disabled, the sensor operate as a
counter / statistic only device.
N/A
enabled
Firmware Version
Downlink this message to retrieve the
firmware information
N/A
N/A
For information on decoding and encoding the sensor messages please visit the product page
at
Cora CS1040 Vibration Sensor - Codepoint Technologies