Part 3 Electrical Connection
Dimensions
Dimensions Data & Amperage
Model
A
B
C
D
Amps
13
6
8
1.26
2.99
4.84
WARNING:
Ensure the power supply is disconnected before
proceeding.
Verify that the power supply matches the ratings found
on the blower data label before proceeding.
The complete blower unit must be properly grounded at
all times when electrical power is applied.
Do not ground the appliance with the neutral (white)
house supply wire. A separate ground wire must
be
utilized.
Failure to complete electrical connections properly may
result in damaged or non-functional systems. Follow
instructions carefully to ensure proper installation.
Black
120 volt AC from electrical panel (usually black) to liner
White
Neutral from electrical panel (white) to liner
Green
Ground from electrical panel (usually green) to liner
Red
120 volt AC variable control from liner to 120 volt AC of variable speed ventilator (usually black)
CAUTION:
Do
NOT
connect this wire to a 3-speed blower.
Liner Models:
CSPI Series
CSCI Series
Excluding...
3-speed motor
models, which all
have a
-6 or -12
at the end of
model number.
BLK
WHT
GRN
RED
Ventilator
Liner
House Electrical
Panel
Green
White (N)
120V Black
(L)
120V Red
Green, Ground
3/4”
A B
C
D
Wiring Diagram (for connecting “Remote” blowers to CopperSmith Pro & Standard Series liners*)
It is the owner’s responsibility to ensure that a qualified person performs the electrical connection of this appliance. The electrical installa-
tion, including minimum supply wire size, must comply with the National Electric Code ANSI/NFPA 70-1990 (or latest revision) and local
codes and ordinances. A copy of this standard may be obtained from: National Fire Protection Assoc., 1 Batterymarch Park, Quincy, MA
02269
Green/Yellow
Blue
Black
Brown
Capacitor
(Ground)
N (White)
L (Black)
115 Volt Single Phase Fans
Motor
Leads
Control
Voltage
From
Switch
In Hood
Page 5
CopperSmith, Remote Blower Installation Instructions (All Models), Revised 09-18-16